Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Part 1 Multi-Split Type Air Conditioners 2/3/4MXS-N Series
- Power Supply
- Functions
- Specifications
- Outdoor Unit
- Combination Capacity: 2MXS18NMVJU
- Combination Capacity: 3MXS24NMVJU
- Combination Capacity: 4MXS36NMVJU
- Dimensions
- Wiring Diagrams
- wiring diagram
- Piping Diagrams
- Capacity Tables
- MXS24NMVJU
- MXS36NMVJU
- Operation Limit
- Fan Characteristics
- Sound Level
- Indoor Unit
- Electric Characteristics
- Part 2 Installation Manual
- CTXG Series
- CTXS, FTXS, CDXS, FDXS Series
- CTXS07LVJU, FTXS09/12LVJU
- FTXS15/18/24LVJU
- FDXS09/12LVJU, CDXS15/18/24LVJU
- FVXS Series
- FFQ Series
- BYFQ60B3W1> Decoration Panel
- BYFQ60C2W1W(S)> Decoration Panel
- BRC1E73> Wired Remote Controller
- BRC082A41W, BRC082A42W(S)> Wireless Remote Controller
- Part 3 Operation Manual
- CTXG, CTXS, FTXS, CDXS, FDXS, FVXS Series
- Safety Considerations
- Names of Parts
- Preparation before Operation
- AUTO · DRY · COOL · HEAT · FAN Operation
- Adjusting the Airflow Direction and Rate
- COMFORT AIRFLOW / INTELLIGENT EYE Operation
- POWERFUL Operation
- POWERFUL / ECONO / OUTDOOR UNIT QUIET Operation
- ECONO / OUTDOOR UNIT QUIET Operation
- OUTDOOR UNIT QUIET Operation
- ECONO Operation
- TIMER Operation
- WEEKLY TIMER Operation
- Note for Multi System
- Care and Cleaning
- Troubleshooting
- Quick Reference
- With <BRC1E73> Wired Remote Controller
- Part 4 Options
- Option List
- Control Devices
- BRC944B2> Wired Remote Controller
- KRP1C75> Adaptor for Wiring
- KRP4A74> Wiring Adaptor for Electrical Appendices
- KRP1BA101> Installation Box for Adaptor PCB
- KRCS01-4B> Remote Sensor
- Options for Indoor Unit
- BRYQ60A2W(S)> Sensor Kit
- KDBQ44BA60A> Panel Spacer
- installation of the decoration panel
- KDDQ44XA60> Fresh Air Intake Kit
- Options for Outdoor Unit
- KKG063A42> Back Protection Wire Net
- KKG063A43> Side Protection Wire Net
|
EDUS121503A Options for Indoor UnitOptions 64543. Options for Indoor Unit3.1 Insulation Kit for High Humidity380When moving the unit at or after opening, hold the unit by the hanger brackets.Do not apply force to the refrigerant piping, drain piping or flange parts.Side plate (right)SlitSlitSlitB C240207Slit1104A904KDT25N63Kit nameKDT25N50420207ScoreKDT25N63Kit nameKDT25N501100A900Hanger brackets (right)90SlitKDT25N50, KDT25N63 model only90380390How to attachScoreKit name A1021821KDT25N63KDT25N503 Stick the insulations carefully according to the following proceduresand do not make a gap between the adjacent thermal insulations.(1) Stick the top plate insulation T-1 , T-2 to the indoor unit top plate.(2) Cut off the side plate insulation S-1 following the score.(See the right figure)(3) Stick the side plate insulation S-1 to the indoor unit right side plate.(4) Stick the side plate insulation S-1 to the indoor unit left side platewithout cutting off the area surrounded by the score.(5) Stick the side plate insulation S-2 to the indoor unit left side plate.(6) Stick the bottom plate insulation B-1 to the indoor unit bottom plate.(7) Stick the chamber cover insulation C-1 to the indoor unit chamber cover.(8) Stick the hanger (left) insulation H-2 and the hanger (right) insulation H-1to the left and right hangers respectively.(See the right figure for the sticking reference.)SlitKDT25N63Kit name AKDT25N50 9001100240ARROW VIEW A200Slit390Designation Side plate insulation S-1KDT25N32(mm)1 pc.(mm)When the Installation box for adapter PCB(KRP1BA101)is used together, mount this kit before Installation box.Bottom plate insulation B-1Top plate insulation T-21 pc.Details of partsHanger (right) insulation H-1( This instruction )VRV model onlyNumber ofpiecesDesignationHanger (left) insulation H-2Designation700Number ofpiecesCut off the area shown with oblique lines and throw it away.Shape(mm)621Chamber cover insulation C-1AKDT25N32DETAIL B700It is recommended to mount this kit before installing the indoor unit.KDT25N32Hanger bracket (left)2 pcs.Shape1 pc.ShapeVRV and Room Air conditioners1 pc.(mm)Side plate (left)(mm)(mm)1 pc. 1 pc.Installation manualCautionThis kit can be installed to the Ceiling mounted Built-in Type Air Conditioners.7041 pc.Top plate insulation T-1(mm)Side plate insulation S-21 pc.Sticking referenceNumber ofpiecesKDT25N32DETAIL C(mm)157268 9A A4A AC-1S-1H-1H-2 H-1B-1S-2H-2S-1T-2T-1« »Kit nameKDT25N32 KDT25N50CDXS15/18LVJUFDXS09/12LVJUKDT25N63Combination tableC: 3P131323-1E
PreviousNext |