Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Part 1 Multi-Split Type Air Conditioners 2/3/4MXS-N Series
- Power Supply
- Functions
- Specifications
- Outdoor Unit
- Combination Capacity: 2MXS18NMVJU
- Combination Capacity: 3MXS24NMVJU
- Combination Capacity: 4MXS36NMVJU
- Dimensions
- Wiring Diagrams
- wiring diagram
- Piping Diagrams
- Capacity Tables
- MXS24NMVJU
- MXS36NMVJU
- Operation Limit
- Fan Characteristics
- Sound Level
- Indoor Unit
- Electric Characteristics
- Part 2 Installation Manual
- CTXG Series
- CTXS, FTXS, CDXS, FDXS Series
- CTXS07LVJU, FTXS09/12LVJU
- FTXS15/18/24LVJU
- FDXS09/12LVJU, CDXS15/18/24LVJU
- FVXS Series
- FFQ Series
- BYFQ60B3W1> Decoration Panel
- BYFQ60C2W1W(S)> Decoration Panel
- BRC1E73> Wired Remote Controller
- BRC082A41W, BRC082A42W(S)> Wireless Remote Controller
- Part 3 Operation Manual
- CTXG, CTXS, FTXS, CDXS, FDXS, FVXS Series
- Safety Considerations
- Names of Parts
- Preparation before Operation
- AUTO · DRY · COOL · HEAT · FAN Operation
- Adjusting the Airflow Direction and Rate
- COMFORT AIRFLOW / INTELLIGENT EYE Operation
- POWERFUL Operation
- POWERFUL / ECONO / OUTDOOR UNIT QUIET Operation
- ECONO / OUTDOOR UNIT QUIET Operation
- OUTDOOR UNIT QUIET Operation
- ECONO Operation
- TIMER Operation
- WEEKLY TIMER Operation
- Note for Multi System
- Care and Cleaning
- Troubleshooting
- Quick Reference
- With <BRC1E73> Wired Remote Controller
- Part 4 Options
- Option List
- Control Devices
- BRC944B2> Wired Remote Controller
- KRP1C75> Adaptor for Wiring
- KRP4A74> Wiring Adaptor for Electrical Appendices
- KRP1BA101> Installation Box for Adaptor PCB
- KRCS01-4B> Remote Sensor
- Options for Indoor Unit
- BRYQ60A2W(S)> Sensor Kit
- KDBQ44BA60A> Panel Spacer
- installation of the decoration panel
- KDDQ44XA60> Fresh Air Intake Kit
- Options for Outdoor Unit
- KKG063A42> Back Protection Wire Net
- KKG063A43> Side Protection Wire Net
|
EDUS121503A DimensionsMulti-Split Type Air Conditioners 2/3/4MXS-N Series 7314. Dimensions4.1 Indoor UnitCTXG09/12QVJUW(S)CTXG18QVJUW(S)REAR REAR1-3/16 (30) MIN1-15/16 (50) MIN1-15/16 (50) MIN9-13/16 (250) MIN13-3/4 (350) MIN19-11/16 (500) MINBOTTOMBOTTOMFLAPSφ11/16 (18)φ5/8 (16)39-5/16 (998)26-9/16 (674.5)2-5/16 (59) 7/8 (21.5)UP/DOWN (AUTOMATIC)COOLING, DRY HEATING FAN25˚30˚30˚10-5/8 (270.5)7-7/16 (189)50˚50˚ 65˚35˚35˚(ARC466A36)39-5/16 (998)GENERAL RATINGNAME PLATE11-15/16 (303)SERVICE COVER FIXEDSCREW (ON FRONT GRILLE)NOTE) 1.THE MARK (→) SHOWS PIPING DIRECTION.LEFT←↑ ↑OPERATING STATE:1) OFFTERMINAL BLOCKWITH GROUND TERMINAL(INSIDE)INCLUDINGMOUNTING PLATE8-3/8 (212)8-7/16 (214)2) ON↓↓ INTELLIGENTEYE SENSORMULTI-MONITOR LAMPTIMER LAMPFRONT GRILLE FIXED SCREWS(INSIDE PANEL)INTELLIGENTEYE LAMPINDOOR UNIT ON/OFF SWITCHROOM TEMPERATURETHERMISTOR (INNER)SIGNAL RECEIVERSIGNAL TRANSMITTERUP AND DOWN WINDDIRECTION CONTROL BLADEMOVABLE RANGE11/16 (18)9-3/8 (238)WIRELESS REMOTE CONTROLLERBLADE ANGLELEFT/RIGHT(AUTOMATIC)REQUIRED SPACEFOR INSTALLATIONAIRFLOW (INDOOR)(SPACE FOROPERATION)(SPACE FORRECEIVING)(SPACE FORRECEIVING)(SPACE FOROPERATION)(SPACE FORPERFORMANCE)(SPACE FORRECEIVING)DRAIN HOSE CONNECTING PARTGAS PIPE φ3/8 (9.5) CuT(THE LENGTH OF PIPE OUTSIDETHE UNIT: ABOUT 13-3/4 (350))LIQUID PIPE φ1/4 (6.4) CuT(THE LENGTH OF PIPE OUTSIDETHE UNIT: ABOUT 15-3/4 (400)) THE HOSE LENGTH OF OUTSIDETHE UNIT IS APPROX. 18-5/16 (465)13/16 (20)BACK SIDE VIEW7-7/8 (200)5-15/16 (151)5-9/16 (142) STANDARD LOCATIONS OF WALL HOLESWALL HOLEφ2-9/16 (65)WALL HOLEφ2-9/16 (65) 11-15/16 (303)1-15/16 (49)1-15/16 (49) 13/16 (20)C: 3D105568AIRFLOW (INDOOR)39-5/16 (998)REAR REAR1-3/16 (30) MIN11-15/16 (303)1-15/16 (50) MIN1-15/16 (50) MIN8-3/8 (212)8-7/16 (214) 13-3/4 (350) MIN 9-13/16 (250) MIN2) ON19-11/16 (500) MINBOTTOM 11/16 (18)BOTTOM9-3/8 (238)FLAPSφ11/16 (18)φ5/8 (16)39-5/16 (998)26-9/16 (674.5) 7-7/8 (200)2-5/16 (59) 7/8 (21.5)13/16 (20)13/16 (20)UP/DOWN (AUTOMATIC)COOLING, DRY HEATING FAN1-15/16 (49)25˚30˚1-15/16 (49)11-15/16 (303)30˚10-5/8 (270.5)7-7/16 (189)50˚50˚ 65˚ 5-15/16 (151)5-9/16 (142)35˚35˚(ARC466A36)NOTE) 1. THE MARK (→) SHOWS PIPING DIRECTION.LEFT←↑ ↑↓ ↓GENERAL RATINGNAME PLATESERVICE COVER FIXEDSCREW (ON FRONT GRILLE)FRONT GRILLE FIXED SCREWS(INSIDE PANEL)INTELLIGENTEYE SENSORMULTI-MONITOR LAMPTIMER LAMP INTELLIGENTEYE LAMPINDOOR UNIT ON/OFF SWITCHROOM TEMPERATURETHERMISTOR (INNER)SIGNAL RECEIVERSIGNAL TRANSMITTERWIRELESS REMOTE CONTROLLERBLADE ANGLELEFT/RIGHT(AUTOMATIC)WALL HOLEφ2-9/16 (65)WALL HOLEφ2-9/16 (65)STANDARD LOCATIONS OF WALL HOLESBACK SIDE VIEWOPERATING STATE:1) OFFTERMINAL BLOCKWITH GROUNDTERMINAL (INSIDE)INCLUDINGMOUNTING PLATEREQUIRED SPACEFOR INSTALLATIONUP AND DOWN WINDDIRECTION CONTROL BLADEMOVABLE RANGE(SPACE FOROPERATION)(SPACE FORRECEIVING)(SPACE FORRECEIVING)(SPACE FOROPERATION)(SPACE FORPERFORMANCE)(SPACE FORRECEIVING)GAS PIPE φ1/2 (12.7) CuT(THE LENGTH OF PIPE OUTSIDETHE UNIT: ABOUT 13-3/4 (350))LIQUID PIPE φ1/4 (6.4) CuT(THE LENGTH OF PIPE OUTSIDETHE UNIT: ABOUT 15-3/4 (400))DRAIN HOSE CONNECTING PARTTHE HOSE LENGTH OF OUTSIDETHE UNIT IS APPROX. 18-5/16 (465)C: 3D105569
PreviousNext |