8 Technical dataInstallation manual24EBLQ+EDLQ011~016CAV3+W1Daikin Altherma low temperature monobloc4P522031-1 – 2018.01Refrigerant flow – heating8.2 Wiring diagram: Outdoor unitSee the internal wiring diagram supplied with the unit (on the inside of the front plate). The abbreviations used are listed below.(1) Connection diagramEnglish TranslationConnection diagram Connection diagramOutdoor OutdoorON ONOFF OFFSee note *** See note ***Upper Fan Upper fanLower Fan Lower fanInjection InjectionMain Main(2) LayoutEnglish TranslationFront FrontPosition of compressor terminal Position of compressor terminal(3) NotesEnglish TranslationNotes NotesConnectionX1M Main terminalEarth wiringField supplyOptionSwitch boxPCBWiring depending on modelProtective earthField wireNOTES:1 Refer to the wiring diagram sticker (on the back of the servicecover) for how to use the BS1~BS4 and DS1 switches.2 When operating, do not short-circuit protective devices S1PH,S1PL and S1NPH3 Refer to the combination table and the option manual for howto connect the wiring to X6A.4 Colours: BLK: black; RED: red; BLU: blue; WHT: white; GRN:green; YLW: yellow5 Confirm the method of setting the selector switches (DS1) byservice manual. Factory setting of all switches: OFF.(4) LegendA1P Printed circuit board (main)A2P (V3 only) Printed circuit board (service)A2P (W1 only) Printed circuit board (inverter)A3P Printed circuit board (noise filter)A4P (V3 only) Printed circuit board (communication)BS1~BS4 (A2P) Push-button switchC1~C4 (A1P)(V3only)CapacitorC1~C3 (A2P)(W1only)CapacitorDS1 (A2P) DIP switchE1H * Bottom plate heaterE1HC Crankcase heaterF1U, F3U, F4U(A1P~A4P) (V3only)Fuse T 6.3 A 250 VF6U (A1P) (V3only)Fuse T 5 A 250 VF7U, F8U (V3only)* Fuse F 1 A 250 VF1U, F2U (A1P)(W1 only)Fuse T 31.5 A 500 VF3U~F6U (A1P)(W1 only)Fuse T 6.3 A 500 VF7U (A2P) (W1only)Fuse T 5 A 250 VF8U, F9U (W1only)* Fuse F 1 A 250 VH1P~H7P (A2P) LED (service monitor is orange)HAP (A1P)(V3only)LED (service monitor is green)HAP (A1P~A2P)(W1 only)LED (service monitor is green)K1M~K2M (A2P)(W1 only)Magnetic contactor (main-upload)K1R (A1P) Magnetic relay (Y1S)K1R (A2P)(W1only)Magnetic relay (upload)K2R (A1P)(V3only)Magnetic relay (Y3S)K3R (A1P)(V3only)Magnetic relay (E1H)K2R (A1P)(W1only)Magnetic relay (E1H)K3R (A1P)(W1only)Magnetic relay (Y3S)K4R (A1P) Magnetic relay (E1HC)K10R (A1P)(V3only)Magnetic relay (upload)K11R (A1P)(V3only)Magnetic relay (main)L1R (V3 only) ReactorL1R~L3R (W1only)ReactorL4R (W1 only) Reactor (outdoor fan motor)M1C Compressor motorM1F, M2F Fan motorPS (A1P)(V3 only) Switching power supplyPS (A2P)(W1only)Switching power supplyQ1DI # Earth leakage circuit breaker (30 mA)R1, R2 (A1P) (V3only)Resistor