5 InstallationInstallation manual6(C)(F)TXA15~50A2V1B(W)(S)(T)Daikin room air conditioner3P482320-7H – 2018.02baa Hookb Flat screwdriverTo re-install the front grille1 Install the front grille and firmly engage the 3 upper hooks.2 Tighten the 2 screws and put the 2 screw covers back.3 Re-install the flap.4 Insert the wire harness back into the connector and secure itwith the wire clamp.5 Close the front panel. Refer to "To close the front panel" onpage 4.To remove the electrical wiring box cover1 Remove the front grille.2 Remove 1 screw from the electrical wiring box.3 Open the electrical wiring box cover by pulling it to the front.4 Remove the electrical wiring box cover from the 2 rear hooks.12bacca Screwb Electrical wiring boxc Rear hook5 To re-install the cover, first attach the electrical wiring box to thehooks, close the electrical wiring box, and re-install the screw.NOTICEWhen closing the electrical wiring box cover, make surethat the tightening torque does NOT exceed2.0 (±0.2) N•m.5.2 Installing the indoor unit5.2.1 To install the mounting plate1 Install the mounting plate temporarily.2 Level the mounting plate.3 Mark the centres of the drilling points on the wall using a tapemeasure. Position the end of tape measure at symbol " ".4 Finish the installation by securing the mounting plate on the wallusing screws.INFORMATIONThe removed pipe port cover can be kept in the mountingplate pocket.Ø80Ø806051710079892444437543049058.6 52.5fjji ibb c edk l maagfahhaa aaa aaaa Recommended mounting plate fixing spotsb Pocket for the pipe port coverc Use tape measure as shown