5 InstallationInstallation manual5CTXM15+ATXM20~50+FTXM20~71N2V1BDaikin room air conditioner3P482320-8K – 2018.09125.1.5 To re-install the front grille1 Install the front grille and firmly engage the 3 upper hooks.2 Install 2 screws (class 15~42) or 3 screws (class 50~71) backon the front grille.3 Install the air filter and then mount the front panel.5.2 Installing the indoor unit5.2.1 To install the mounting plate1 Install the mounting plate temporarily.2 Level the mounting plate.3 Mark the centres of the drilling points on the wall using a tapemeasure. Position the end of tape measure at symbol " ".4 Finish the installation by securing the mounting plate on the wallusing M4×25L screws (field supply).Class 15~42 Class 50~71INFORMATIONThe removed pipe port cover can be kept in the mountingplate pocket.Class 15~42:337810A29444.517068 6844.513713733750213 237170Ade(mm)a afh gaaba c a c adeClass 50~71:A9901040300170601705252122 126.548 60435447PIPING HOLECENTER:170mmTO THE LEFTPIPING HOLECENTER:170mmTO THE LEFT(mm)A142 151.5PIPING HOLECENTER:170mmTO THE LEFTPIPING HOLECENTER:170mmTO THE LEFTeijdedba c a c aaghfaa Recommended mounting plate fixing spotsb Pocket for the pipe port coverc Tabs for placing a spirit leveld Through-the-wall hole:e Drain hose positionf Position for the tape measure at symbol " "g Gas pipe endh Liquid pipe end