312• Heating • Daikin Altherma low temperature split 3• Daikin Altherma low temperature split • EHBX-C2 Specifications2-1 Technical Specifications EHBX04C3V EHBX08C3V EHBX08C9W EHBX16C3V EHBX16C9WPower input Nom. kW 0.075 0.180Casing Colour WhiteMaterial Precoated sheet metalDimensions Unit Height mm 890Width mm 480Depth mm 344Packed unit Height mm 415Width mm 650Depth mm 1,016Weight Unit kg 44 46 48 47 48Packed unit kg 47 49 51 50 52Packing Material Carton / EPS / PP (Straps)Weight kg 2.8Pump Type DC motorNr of speeds Inverter controlledPower input W 45 150Expansion vessel Volume l 10Max. water pressure bar 3Pre pressure bar 1Operation range Heating AmbientMin. ºC -25 -25 (11)Max. ºC 25 35 (11)WatersideMin. ºC 15 (5)Max. ºC 55 (5)Cooling AmbientMin. ºCDB 10Max. ºCDB 43 46WatersideMin. ºC 5Max. ºC 22Domestic hot water AmbientMin. ºCDB -25 -20Max. ºCDB 35WatersideMin. ºC 25Max. ºC 80Water side HeatexchangerType Brazed plateQuantity 1Water volume l 0.9 1.3 1.0Water flow rate Min. l/min 5.0 11.0Heating Max. l/min 25 34 51Cooling Max. l/min 25 34 51Cooling Insulation material Elastomeric foamRefrigerant circuit Gas side diameter mm 15.9Liquid side diameter mm 6.35 9.52Sound power level Nom. dBA 40 (2) 47Sound pressure level Nom. dBA 26 33Water filter Diameter perforations mm 1Material copper - brass - stainless steelWater circuit Piping connections diameter inch G 1"1/4 (female)Safety valve bar 3Manometer YesDrain valve / fill valve YesShut off valve YesAir purge valve YesTotal water volume l 3 (6) 4 (6) 5 (6) 4 (6) 5 (6)PED Category Art3§3 Category I Art3§3Most critical part Name - Plate heat exchanger -Ps*V Bar*l - 51.0 (0.000) -