• Daikin Altherma low temperature split • EHBX-C12• Heating • Daikin Altherma low temperature split42 SpecificationsNotes(1) With option kit *KHBDP installed: Height = XXX mm(2) DB/WB 7ºC/6ºC - LWC 35ºC (DT=5ºC)(3) The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.(4) The sound pressure level mentioned is maximum possible value inside operation range of unit(5) 15ºC-25ºC: BUH only, no heat pump operation = during commisioning(6) Including piping + PHE + back-up heater; excluding expansion vessel(7) Value mentioned is connection after ball valves, Connection at unit is G1-1/4 FEMALE(8) See separate drawing for operation range(9) \> 50ºC BSH only, no heatpump operation(10) BUH 3V/9W can only operate at flow \> 12/15 l/min(11) Refer to operation range for detail for differences between *RHQ* and *RLQ* models(12) PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC2-2 Electrical Specifications EHBX04C3V EHBX08C3V EHBX08C9W EHBX16C3V EHBX16C9WPower supply Voltage range Min. % 10Max. % 10Wiring connections-Communication cableQuantity 3Remark 2.5 mm²Wiring connections-Electric meterQuantity 2Wiring connections-Preferential kWh ratepower supplyQuantity Power: 2Wiring connections-Domestic hot waterpumpQuantity 2Remark Minimum 0.75 mm² (2A inrush, 1A continuous)Wiring connections-For power supplyconnection to optional*KHW*Quantity 3GRemark 13A (Select diameter and type according to national and local regulations)Wiring connections-For connection tooptional *KHW* model+ Q2LQuantity 5GRemark Select diameter and type according to national and local regulations / For more details of the voltagerange and current, refer to installation manualWiring connections-For connection withR5TQuantity Wire included in option *KHW*Remark Wire included in option *KHW*Wiring connections-For connection withR6TQuantity 2Remark Minimum 0.75 mm²Wiring connections-For connection withA3PRemark Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA/ Min. 0.75mm²Wiring connections-For connection withM2SQuantity 2Remark Voltage: 230V / Max.current: 100mA / Min. 0.75mm² / Select diameter & type according to national &local regulationsWiring connections-For connection withM3SQuantity 3Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA/ Min. 0.75mm²Wiring connections-For connection withbottom plate heaterQuantity 2Remark Select diameter and type according to national and local regulationsWiring connections-For connection withuser interfaceQuantity 2Remark 0,75 mm² till 1,25 mm² (max length 500m)Wiring connections-For connection withoptional FWXV*(demand input andoutput)Quantity 4Remark 100 mA, minimum 0.75 mm²Notes PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC