8 ConfigurationInstaller reference guide50ERGA04~08DAV3(A) + EHVH/X04+08S18+23DADaikin Altherma – Low temperature split4P495248-1 – 2017.12Item DescriptionUser settings Gives access to user settings such asholiday mode and quiet mode.Information Displays data and information about theindoor unit.Installer settings Restriction: Only for the installer.Gives access to advanced settings.Commissioning Restriction: Only for the installer.Perform tests and maintenance.User profile Change the active user profile.Operation Turn heating/cooling functionality anddomestic hot water preparation on or off.8.3.4 Menu screenPossible actions on this screenGo through the list.Enter the submenu/setting.8.3.5 Setpoint screenThe setpoint screen is displayed for screens describing systemcomponents that need a setpoint value.Example:▪ Room temperature screen▪ Main zone screen▪ Additional zone screen▪ Tank temperature screena1d+–de deca2b1b2Possible actions on this screenGo through the list of the submenu.Go to the submenu.Adjust and automatically apply the desiredtemperature.Item DescriptionMinimum temperature limit a1 Fixed by the unita2 Restricted by the installerMaximum temperature limit b1 Fixed by the unitb2 Restricted by the installerCurrent temperature c Measured by the unitDesired temperature d Turn the right dial toincrease/decrease.Submenu e Turn or press the left dial togo to the submenu.8.3.6 Detailed screen with valuesa ba Settingsb ValuesPossible actions on this screenGo through the list of settings.Change the value.Go to the next setting.Confirm changes and proceed.8.3.7 Detailed screen with weather-dependentcurveWhen weather dependent operation is active the desired tanktemperature is determined automatically depending on the averagedoutdoor temperature. When the outdoor temperature is lower thetank temperature will need to be higher as the water pipes will becolder and vice versa.The weather-dependent curves are defined by two setpoints:▪ Setpoint (X1, Y2)▪ Setpoint (X2, Y1)Weather-dependent curve:X1Y1Y2X2Y aXPossible actions on this screenGo through the temperatures.Change the temperature.Go to the next temperature.Confirm changes and proceed.Item Descriptiona Possible weather dependent zones:▪ : Main zone or additional zone heating▪ : Main zone or additional zone cooling▪ : Domestic hot waterX, X1, X2 Outdoor ambient temperatureY, Y1, Y2 Desired tank temperature or leaving water temperature.The symbol shown here corresponds to the heat emitterfor that zone:▪ : Underfloor heating▪ : Fan coil unit▪ : Radiator▪ : Domestic hot water tankFinal English - Tanslations in progress