• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB• Split Sky Air • Indoor Units65 Dimensional drawing & centre of gravity5 - 1 Dimensional drawing with standard panelFCQH71D83TW28894-1CNr Name Description1 Liquid pipe connection ø 9.52 flare connection2 Gas pipe connection ø 15.90 flare connection3 Drain pipe connection VP25 (O.D. ø32, I.D. ø25)4 Power supply connection5 Transmission wiring connection6 Air discharge opening7 Air suction grill8 Corner decoration cover9 Drain house O.D. ø32 I.D. ø26View ANOTES1 Location of the nameplates:- Unit body: on the control box cover.- Decoration panel: on the panel frame at the motor sideunder the cover2 When installing an optional accessory, refer to the installation- For the fresh air intake kit ... an inspection port is necessaryDrain sidePiping sideSee note 3860 - 910 (Ceiling opening)710 (Suspension position)See note 4860 - 910 (Ceiling opening)780 (Suspension position)See note 4 See note 495095042042055 55840340280330Hanging bolt4 x M8-M10504024610850Adjustable (0-675)25616517512535 3555 8401301500 or more(Instaalation space)200 mmor more1500 mmor more (*)1500 mmor more (*)1500 mmor more (*)200 mmor moreVentilator Other unitExternal surfacelight1500 mm or more2000 mm or more4000 mm or more123 In case of using a Infrared remote control, this position will be a signal receiver.Refer to the drawing of the infrared remote control for more detail4 Make sure the spacing between the ceiling and the cassette is no more than 35 mm. Max ceiling opening: 910 mm.5 When the conditions exceed 30°C and RH 80% in the ceiling or fresh air is inducted, into the ceiling, an additionalinsulation is required (polyethylene foam, thickness 10 mm or more.)(*) In case a discharge opening is closed with the ‘sealing member’ option, the distance of 1500 mm can be reduced to 500 mm on the closed side.300 or less1500 mmor more (*)55FCQH100-140D83TW28914-1CPiping sideDrain sidesee note 3see note 4300 or less(Ceiling opening)(Suspension position)(Suspension position)(Ceiling opening)Please respect the distances as shown on figure belowOther unitVentilatorExternalsurfacelight1500 or more2000 or more4000 or more1500 mmor more (*)1500 mmor more (*)1500 mmor more (*)1500 mmor more (*)200 mmor more200 mmor more(*) In case a discharge opening is closed withthe “sealing member” option, the distance of1500 mm can be reduced to 500 mm on theclosed side.see note 4see note 4Hanging bolt adjustable1500 or more(Suspension position)View A View BItem Name Remark1 Liquid pipe connection ø9.52 (Flare connection)2 Gas pipe connection ø15.90 (Flare connection)3 Drain pipe connection VP25 (ODø32, IDø25)4 Power supply entry hole5 Transmission wiring entry hole6 Air discharge opening7 Air suction grille8 Corner decoration cover9 Drain hose ODø32, IDø2510 Knock out holeNOTE1 Location of the nameplates - Unit body: on the control box - Decoration panel: on the panel frame at the motor side under the corner cover2 When installing an optional accessory, refer to the installation drawingsFor the fresh air intake kit an inspection port is necessary3 In case of using a wireles remote control, this position will be a signal receiver. Refer to the drawing of the wireless remote control for more detail.4 Make sure the spacing between the ceiling and the cassette is no more than 35mm. Max cailing opening: 910mm.5 When the conditions exceed 30°C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additionalinsulation is required (polyethylene foam,thickness 10mm or more).