Dimensions EDUS09161710 Split Type Air Conditioners FFQ-Q Series4.2 Outdoor UnitRX09/12QMVJURX15QMVJUOUTDOOR AIR THERMISTOR 9/16 (15) 26-9/16 (675) 1-5/16 (50) 5/16 (8)HANDLE 1/2 (12.4)11-3/16 (284)13/16 (20) GROUNDBRAND NAME PLATE4-1/8 (104)6-7/16 (164)21-5/8 (550)6-1/4 (159)13/16 (20)*A*B12-1/8 (308)12-13/16 (326)*A*A16-1/16 (408)1/2 (13)18-1/2 (470) 3-13/16 (97)1-1/8 (29)MINIMUM SPACE FOR AIR PASSAGE5-7/8 (150)1-15/16 (50)5-7/8 (150)3-15/16 (100)1-15/16 (50) 1-15/16 (50)3-15/16 (100)1-15/16 (50)UNIT: inch (mm)11-13/16 (300)MANUFACTURER'SLABELSERVICEPORTSTOP VALVECOVERLIQUIDSTOP VALVE(φ1/4 (φ6.4) CuT)GASSTOP VALVE(φ3/8 (φ9.5) CuT)IN CASE OF REMOVINGSTOP VALVE COVER4-HOLES FOR FOUNDATION BOLTS5/16 OR 3/8 (M8 OR M10)WALL HEIGHT ON AIR OUTLET SIDE=LESS THAN 47-1/4 (1200)*A, *B DRAIN OUTLETWHEN CONDUCTING CONCENTRATEDDRAIN PIPING WORK, ATTACH THESUPPLIED DRAIN CAPS.DRAIN OUTLET(I,D φ5/8 (φ15.9mm) HOSE FOR CONNECTIONWITH DRAIN JOINT)3D092206BHANDLE 34-1/4 (870)9/16 (14) 2-3/4 (70)OUTDOOR AIR THERMISTOR1-3/16 (30)12-5/8 (320)1/4 (7) ELECTRIC WIRE INTAKEBRAND NAME PLATEMANUFACTURER'S LABEL3/4 (19)28-15/16 (735)7/8 (23)9/16 (14.5)4-15/16 (125)23-5/8 (600) 13-5/8 (346) 7/16 (11)14-1/2 (368)GROUND TERMINAL MINIMUM SPACE FOR AIR PASSAGE11-7/16 (291)3-15/16 (100)20-11/16 (525)1-15/16 (50)1-15/16 (50) 1-15/16 (50)13-3/4 (350)3-15/16 (100)3-15/16 (100)13-3/4 (350)4-1/8 (105)6-1/2 (165)13-3/4 (350)UNIT: inch (mm)6-13/16 (173)4-HOLES FOR FOUNDATION BOLTS(M8 OR M10)(INSTALLATION LEGPITCH)WALL HEIGHT ON AIR OUTLET SIDE=LESS THAN 47-1/4 (1200)DRAIN OUTLET(I,D φ5/8 (φ15.9) HOSE FORCONNECTION WITH DRAIN JOINT)LIQUIDSTOP VALVE(φ1/4 (φ6.4) CuT)GASSTOP VALVE(φ1/2 (φ12.7) CuT)SERVICEPORTIN CASE OF REMOVINGSTOP VALVE COVER ANDTERMINAL STRIP COVER C: 3D092224A