Option List EDUS091617164 Split Type Air Conditioners FFQ-Q Series13.4 Wiring Adaptor for Electrical AppendicesAdaptorAdaptorService monitor (H10P: Red)×1Service monitor (H1P: Green)Transmission wiring (P1,P2) SS2Clamp(Ex.)When individually controlling 8 unitsNames of parts and functionSystem outlineTerminal board for display signal (X3M)1. Individual control (Each indoor unit is controlled individually.)(2)Indoor unitBRC1E71 ×8 kitsNote) Connector No. X35AKRP4A74 ×8 kits×3Adaptor2. Group control (Multiple indoor units are controlled as a group.)This system requires the following parts.Remote control input terminal board (X1M)Remote controllerPower supply connectorTo outdoor unitChangeover switch (SS1) (Factory set: Volt)×1Accessories Check if the following accessories are included in the kit.Relay harness(1) ×1 eachRemote controllerIndoor unit max. 16 unitsThis system requires the following parts.PCB supportInstallation manualTo outdoor unit×4• Adaptor........................................................................KRP4A74• Remote controller (For operation control)....................BRC1E71• Adaptor........................................................................ KRP4A74• Remote controller (For operation control)....................BRC1E71Lid of installation boxPCB supportInstallation box for adaptor PCBAdaptor(KRP4A74)KRP1BA101 (Optional accessory)InstallationThis kit enables remote control (ON/OFF control, temperature setting, operation display, error display) and can be used with thefollowing systems though it cannot be used in conjunction with other optional controllers for centralized control.This lamp flashes while theCPU is operating normally.To connector on indoorunit PCB.To P1 and P2 on indoorunit terminal board.Connects control input from the remote control(Central control monitor, timer, etc.).Set to "Non volt" to input a no-voltagenormally open contactor on the remotecontrol input terminal board (TeS1).This lamp lights up when troubleoccurs in electrical wiring or settingswitches. Remote control is disabled.(This LED is out in constant operation.)Connects operation and error output to aremote point (Central control monitor, etc.).(Normal operation: W1, W2; Error: W3, W4)Temperature setting ON/OFF switch (SS2)(Factory set: Possible)Do not change to "Impossible".Otherwise, temperature settingby the remote control cannot bemade.ImpossiblePossibleControl mode selector switch (RS1)(Factory set: 0)For selecting the type of systemoperation permitted via remote.This function cannot be used forthis kit. Never apply voltage tothis for any reason whatsoever.Temperature setting inputterminal (X2M) For details, seethe electric wiring.To centralcontrol monitorKRP1BA101(Optional accessory)Note: Installation box for adaptor PCB is required to install the adaptor.To centralcontrol monitor1P161220-1A