3EnglishMODELIndoor OutdoorFT20FV1M R20FV1MFT25FV1M R25FV1MFT35FV1M R35FV1MFT50FV1M R50FY1MFT60FV1M9 R60FV1M9This manual provides the procedures of installation to ensure a safe and good standard of operation for the air condi-tioner unit.Special adjustment may be necessary to suit local requirements.Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.INSTALLATION MANUALSAFETY PRECAUTIONS! CAUTIONPlease take note of the following important points when installing.• Do not install the unit where leakage of flammable gas may occur.If gas leaks and accumulates around the unit. it may cause fireignition.• Ensure that the drainage piping is connected properly.If the drainage piping is not connected properly. it may causewater leakage which will dampen the furniture.• Do not overcharge the unit.This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor.• Ensure that the units panel is closed after service or installation.Unsecured panels will cause the unit to operate noisily.• Sharp edges and coil surfaces are potential locations which maycause injury hazards. Avoid from being in contact with theseplaces.• Before turning off the power supply. set the remote controller’sON/OFF switch to the “OFF” position to prevent the nuisancetripping of the unit. If this is not done. the unit’s fans will start turningautomatically when power resumes. posing a hazard to servicepersonnel or the user.• Do not operate any heating apparatus too close to the airconditioner unit. This may cause the plastic panel to melt or deformas a result of the excessive heat.• Ensure the color of wires of the outdoor unit and the terminalmarkings are same to the indoors respectively.• IMPORTANT : DO NOT INSTALL OR USE THE AIRCONDITIONER UNIT IN A LAUNDRY ROOM.! WARNING• Installation and maintenance should be performed byqualified persons who are familiar with local code andregulation. and experienced with this type ofappliance.• All field wiring must be installed in accordance withthe national wiring regulation.• Ensure that the rated voltage of the unit correspondsto that of the name plate before commencing wiringwork according to the wiring diagram.• The unit must be GROUNDED to prevent possiblehazard due to insulation failure.• All electrical wiring must not touch the refrigerantpiping or any moving parts of the fan motors.• Confirm that the unit has been switched OFF beforeinstalling or servicing the unit.• Disconnect from the main power supply beforeservicing the air conditioner unit.• DO NOT pull out the power cord when the power isON. This may cause serious electrical shocks whichmay result in the fire hazards.INSTALLATION OF THE OUTDOOR UNITThe outdoor unit must be installed in such a way, so as to prevent short circuit of the hotdischarged air or obstruction to the smooth air flow. Please follow the installation clearancesshown in the figure. Select the coolest possible place where intake air temperature is notgreater than the outside air temperature (maximum 45°C).Dimension A B C DMinimum Distance, 300 1000 300 500mm (in) (11.8) (39.4) (11.8) (19.7)Installation ClearancesNote: If there is any obstacle higher than 2m, or if there is any obstruction atthe upper part of the unit, please allow more space than the figure indicated inthe above table.ObstacleReturn AirDischarge AirObstacleA BC DObstacleReturn AirServiceAccessObstacle