Main Functions SiUS091601E29 Functions and Control1.8 NIGHT SET ModeOutline When the OFF TIMER is set, NIGHT SET Mode is automatically activated. NIGHT SET Modekeeps the airflow rate setting.Detail NIGHT SET Mode continues operation at the target temperature for the first one hour, thenautomatically raises the target temperature slightly in the case of cooling, or lowers it slightly in thecase of heating. This prevents excessive cooling in summer and excessive heating in winter toensure comfortable sleeping conditions, and also conserves electricity.CoolingHeating1.9 ECONO OperationOutline ECONO operation reduces the maximum power consumption. This operation is particularlyconvenient for energy-saving. It is also a major bonus when breaker capacity does not allow theuse of multiple electrical devices and air conditioners.It can be easily activated by pushing ECONO button on the wireless remote controller.Detail When this function is activated, the maximum capacity also decreases. The remote controller can send the ECONO command when the unit is in cooling, heating, dry,or automatic operation. This function can only be set when the unit is running. Press ON/OFFbutton on the remote controller to cancel the function. This function and POWERFUL operation cannot be used at the same time. The latest commandhas the priority.(R21657)TIMER operationNIGHT SET Mode ONTarget temperature+0.5˚C (+0.9˚F)temperature shiftOperation stopsat the set hours0.5˚C (0.9˚F)1 hourTIMER operationNIGHT SET Mode ONTarget temperature–2˚C (–3.6˚F)temperature shift1 hour2˚C (3.6˚F)(R21658)ECONO operation(R21051)Normal operationMaximum during normal operationMaximum during ECONO operationTimePowerconsumption