Main Functions SiENBE04-925_A30 Function and Control2. Motions (for example: in cooling) When the microcomputer does not have a signal from the sensor in 20 minutes, it judgesthat nobody is in the room and operates the unit in temperature shifted from the targettemperature. (Cooling / Dry : 2°C higher, Heating : 2°C lower, Auto : according to theoperation mode at that time.)H1 In case of FAN mode, the fan speed reduces by 60 rpm.3. Airflow direction in 2-area INTELLIGENT EYE operation Detection method: The opposite area of detected area is set as the target direction.1. Detection signal ON in both area A and B: Shift the airflow direction to area B (left side)2. Detection signal ON in area A: Shift the airflow direction to area B (left side)3. Detection signal ON in area B: Shift the airflow direction to area A (right side)4. Detection signal OFF in both area A and B: No change* When the detection signal is OFF for 20 minutes in both area A and B, the unit starts energysaving operation.Others For dry operation, you cannot set the temperature with remote control, but internally thetarget temperature is shifted by 2°C.ONOFF RESET.(From area A or B)20 min. 20 min.ONOFFONOFFOperationOFFFan speed (H1)Set speed Set speedTarget temperature(R12183)Remote controlINTELLIGENT EYEbuttonONOFFINTELLIGENT EYElampHuman detectionsignalwithin 20minutesTop viewWallIndoor unitArea AArea BLeft RightHuman(R3853)