SiBE06-514A Main FunctionsFunction and Control 231.5 Programme Dry FunctionProgramme dry function removes humidity while preventing the room temperature fromlowering.Since the microcomputer controls both the temperature and air flow volume, the temperatureadjustment and fan adjustment buttons are inoperable in this mode.In Case ofInverter UnitsThe microcomputer automatically sets the temperature and fan settings. The differencebetween the room temperature at startup and the temperature set by the microcomputer isdivided into two zones. Then, the unit operates in the dry mode with an appropriate capacity foreach zone to maintain the temperature and humidity at a comfortable level.Room temperature atstartup Temperature (ON point)at which operation starts Frequency switchingpoint Temperature differencefor operation stop24ºC Room temperature atstartup 0.5ºC1.5ºC18ºC 18ºC 1.0ºC17ºC —0.5˚CLHz LHz LHz*55Hz*55HzLHz indicates low frequency. Item marked with varies depending on models.ON pointOFF point 5 min 5 minCompressorcontrol StopStop Stop StopStop StopIndoor unit fan Extra-low air flowExtra-low air flowLow air flowLow air flow(R1359)Frequencyswitchingpoint