• Indoor Units • Round Flow Cassette • FXFQ-PVE915• VRV ® Systems • Indoor Units105 Dimensional drawing & centre of gravity5 - 1 Dimensional drawingFXFQ100,125PV93D058469BPipe connection sideDrain connection sideA Arrow ViewNote 216-M4 Prepared holeSuspention bolt4-M8~M10Connection positionof branch duct(Round shape type)Connection position ofbranch duct(Square-shaped type)860~910 (Ceiling opening space) (Note4)710 (Suspention position)780 (Suspention position)860~910 ( Ceiling opening space) (Note4)300 Or lessB Arrow viewConnection position ofbranch duct(Square-shaped type)Connection position ofbranch duct(Round shape type)Connection positionof branch duct20-M4Prepared hole(Square-shaped type)Connection positionof branch duct(Round shape type)Connection position offresh air intake kit(Direct installation type)(Knock hole)C Arrow viewREQUIRED SPACE35 or less (Note 4)Connection positionof branch ductRound shape type)Connection position ofbranch duct(Square-shaped type)35 or less (Note 4)20-M4 Prepared hole200mm or more1500mm or more1500mm or more200mm or more 1500mm or more1500mm or moreDECORATION PANELNOTE1 Sticking location for manufacture’s label.manufacture’s label for indoor unit:Suction grill inner side’s electric components box’s lid surfacemanufacture’s label for decoration panel:Decoration panel’s corner decoration cover inner surface.2 In case of using infrared remote control, this position will be asignal receiver, refer to the drawing of infrared remote controlin detail.3 When the temperature and humidity in the ceiling exceed30°C and RH 80% or the fresh air is inducted into the ceilingor the unit continues 24 hour operation, an additionalinsulation (Thickness 10mm or more of glasswool orpolyethylene form) is required.4 T hough the installation is acceptable up to maximum of 910mmsquare ceiling opening, keep the clearance of 35mm or less betweenthe indoor unit and the ceiling opening so that the panel overlapallowance can be ensured5 Please do not place the thing been damp and trroubled underan indoor unit. When the case where humidity is 80% or more,and the drain outlet are choked up and the air filter are dirty,dew may fall.BYCP125K-W1 Fresh white 6.5Y 9.5/0.5For height installationFrom the floor side 2500 or more1500mm or more(Required space)When the blow-off grill is closing, the required space is 500 or more, when uniting and closing acorner part (both right and left of the of the blow-off grill to close), it is 200mm or more.Adjustable(0~675)16-M4 HoleItem Name Remark1 Liquid pipe connection ø9.5 (Flare connection)2 Gas pipe connection ø15.9 (Flare connection)3 Drain pipe connection VP25 (ODø32)4 Power-source wiring and a unit wiring connection5 Connection wiring / remote control wiring connection6 Air-outlet7 Suction grille8 Corner decoration cover9 Drain hose (Accessory) Local connection ODø32 (Outlet)(Unit connection ODø26)