EDUS041016 Electric CharacteristicsRoom Air Conditioners J-Series 2310. Electric Characteristics3D066179CRepresentative Unit Combination Power Supply COMP OFM IFMIndoor Unit Outdoor Unit Hz-Volts Voltage Range MCA MOP RLA W FLA W FLAFTKN09JEVJU RKN09JEVJU 60-208 MAX. 60Hz 253VMIN. 60Hz 187V 8.3 15 6.7 59 0.29 40 0.2060-230 6.1 0.26 0.18FTKN12JEVJU RKN12JEVJU 60-208 MAX. 60Hz 253VMIN. 60Hz 187V 8.3 15 6.7 59 0.29 40 0.2060-230 6.1 0.26 0.18FTXN09JEVJU RXN09JEVJU 60-208 MAX. 60Hz 253VMIN. 60Hz 187V 8.3 15 6.7 59 0.29 40 0.2060-230 6.1 0.26 0.18FTXN12JEVJU RXN12JEVJU 60-208 MAX. 60Hz 253VMIN. 60Hz 187V 8.3 15 6.7 59 0.29 40 0.2060-230 6.1 0.26 0.18Symbols: Note:MCA : MIN. CIRCUIT AMPS (A) 1. Maximum allowable voltage variation between phases is 2%.2. Select wire size based on the larger value of MCA.3. Instead of fuse, use circuit breaker.4. Be sure to install an ground leak detector. (One that can handlehigher harmonics.)(This unit uses an inverter, which means that it must be use aground leak detector capable handling high harmonics in order toprevent malfunctioning of the ground leak detector itself.)MOP : MAX. OVERCURRENT PROTECTION (A)RLA : RATED LOAD AMPS (A)OFM : OUTDOOR FAN MOTORIFM : INDOOR FAN MOTORFLA : FULL LOAD AMPS (A)W : FAN MOTOR RATED OUTPUT (W)