EDUS041016 DimensionsRoom Air Conditioners J-Series 74. Dimensions4.1 Indoor UnitsFTKN09/12JEVJUFTXN09/12JEVJUAIRFLOW (INDOOR)THE MARK (→) SHOWS PIPING DIRECTIONREAR 30-5/16(770mm)RIGHTLEFT1-3/16(30mm)MIN.INCLUDINGMOUNTING PLATE(SPACE FORPERFORMANCE)7-7/8(200mm) 1-15/16(50mm)MIN. 1-15/16(50mm)MIN.7-51/64(198mm) (SPACE FOR (SPACE FORFRONT PANEL FIXING SCREWS REQUIRED SPACEMAINTENANCE) MAINTENANCE)(INSIDE)GENERAL RATINGNAME PLATESIGNAL RECEIVERTERMINAL BLOCKOPERATION LAMP WITH EARTHTIMER LAMP TERMINALFFO ONINDOOR UNIT ON/OFF SWITCH (INSIDE)11-9/64(283mm)BOTTOM ROOM TEMP. THERMISTORFLAPS GAS PIPE φ3/8(φ9.5mm) CuT(INSIDE) DRAIN HOSE(THE LENGTH OF PIPE OUTSIDE(CONNECTING PARTTHE UNIT : ABOUT 15-23/64(390mm))I.D.FFO ONLIQUID PIPE φ1/4(φ6.4mm) CuTO.D.φ9/16(φ14mm)φ5/8(φ16mm)(THE LENGTH OF PIPE OUTSIDETHE HOSE LENGTH OF OUTSIDETHE UNIT : ABOUT 17-21/64(440mm))THE UNIT IS ABOUT 17-23/32(450mm))30-5/16(770mm)MODEL NAMESIGNAL TRANSMITTER15/64(6mm)21-39/64(549mm)5/8(16mm)PLATE 3-31/32(101mm)11/16(18mm)2-5/16(58mm)BLADE ANGLE6-49/64(172mm)UP/DOWN (AUTOMATIC)11-9/64(283mm)1-5/8(41.3mm)COOLING DRY FAN5˚5˚ 5˚45˚ 45˚45˚ 2-9/64(54.5mm) 2-1/8(54mm)1-5/8(41.3mm)7-3/8(187mm)WALL HOLE FOR EMBEDDED PIPINGRIGHT/LEFT (MANUAL) φ2-9/16(φ65mm) HOLE WALL HOLEφ2-9/16(φ65mm) HOLESTANDARD LOCATIONS OF WALL HOLESWIRELESS REMOTE CONTROLLER45˚45˚(ARC452A14) 3D065952BAIRFLOW (INDOOR)THE MARK (→) SHOWS PIPING DIRECTIONREAR 30-5/16(770mm)RIGHTLEFT1-3/16(30mm)MIN.INCLUDINGMOUNTING PLATE(SPACE FORPERFORMANCE)7-7/8(200mm) 1-15/16(50mm)MIN.1-15/16(50mm)MIN.7-51/64(198mm) (SPACE FOR (SPACE FORFRONT PANEL FIXING SCREWS REQUIRED SPACEMAINTENANCE) MAINTENANCE)(INSIDE)GENERAL RATINGNAME PLATESIGNAL RECEIVERTERMINAL BLOCKOPERATION LAMP WITH EARTHTIMER LAMP TERMINALFFO ONINDOOR UNIT ON/OFF SWITCH (INSIDE)11-9/64(283mm)BOTTOM ROOM TEMP. THERMISTORFLAPS GAS PIPE φ3/8(φ9.5mm) CuT(INSIDE) DRAIN HOSE(THE LENGTH OF PIPE OUTSIDE(CONNECTING PARTTHE UNIT : ABOUT 15-23/64(390mm))I.D.FFO ONLIQUID PIPE φ1/4(φ6.4mm) CuT O.D.φ9/16(φ14mm)φ5/8(φ16mm)(THE LENGTH OF PIPE OUTSIDE THE HOSE LENGTH OF OUTSIDETHE UNIT : ABOUT 17-21/64(440mm)) THE UNIT IS ABOUT 17-23/32(450mm))30-5/16(770mm)MODEL NAMESIGNAL TRANSMITTER15/64(6mm)21-39/64(549mm)5/8(16mm)PLATE 3-31/32(101mm)11/16(18mm)2-5/16(58mm)BLADE ANGLE6-49/64(172mm)UP/DOWN (AUTOMATIC)11-9/64(283mm)1-5/8(41.3mm)COOLING HEATING DRY5˚5˚ 15˚45˚ 45˚ 2-9/64(54.5mm) 2-1/8(54mm)45˚1-5/8(41.3mm)7-3/8(187mm)FAN WALL HOLE FOR EMBEDDED PIPINGRIGHT/LEFT (MANUAL) φ2-9/16(φ65mm) HOLE WALL HOLE5˚ φ2-9/16(φ65mm) HOLESTANDARD LOCATIONS OF WALL HOLESWIRELESS REMOTE CONTROLLER45˚45˚45˚(ARC452A12) 3D065951B