36• Split - Sky Air • RZQSG-L(8)Y1 17• Outdoor Unit • RZQSG-L(8)Y16 Capacity tables6 - 1 Cooling/Heating Capacity TablesRZQSG140L9V1RZQSG140LY1Cooling HeatingSymbolsAFR: Airflowrate[m³/min]BF: BypassfactorEWB: EnteringwetͲbulbtemperature(°CWB)EDB: EnteringdryͲbulbtemperature(°CDB)TC: Maximumtotalcooling/heatingcapacity[kW]SHC: Sensibleheatcapacity[kW]CPI: CoefficientofthepowerinputPI: Powerinput[kW]compressor+indoorandoutdoorfanmotorsCooling HeatingNotes1. Theratingsshownarenetcapacitieswhichincludeadeductionforindoorfanmotorheat.2. = Maximumatstandardconditions= RatedcapacityandratedcoefficientofthepowerinputThemaximumcapacityisnotguaranteedexceptatstandardconditions.3. SHCisbasedonindoorunitsEWB&EDB.SHCforotherdryͲbulbtemperatures=SHC+SHC*SHC* = SHCcorrectionforotherdryͲbulbtemperatures= 0.02xAFR(m³/min)x(1ͲBF)x(DB*ͲEDB)4. Thecapacitiesarebasedonthefollowingconditions:Outdoorair:85%RHHowever,theoutdoorambientconditionoftheratedcapacityduringheatingoperationis7°CDB/6°CWB.Correspondingrefrigerantpipinglength:5.0mLeveldifference:0m5. CPIisapercentagevaluecomparedtotheratedvaluewhichis1.00.6. Theerrorrateforthisvalueislessthan5%anddependsontheindoorunittype.7. Theheatingperformancetakesintoaccountthedropthatoccursduringdefrostoperation.8. Theairflowrateandbypassfactorarementionedinthetable. 9. Theratedpowerinputforeachmodelismentionedinthetablebelow.Pair PairFCQHG140F FCQG140F FBQ140C FHQG140C FVQ140C FHQ140CA FBQ140D FCQHG140F FCQG140F FBQ140C FHQG140C FVQ140C FHQ140CA FBQ140DCooling 4,17 4,45 4,44 4,45 4,45 4,45 4,38Heating 4,29 4,54 4,54 4,54 4,54 4,54 4,56Twin TwinFCQHG71FX2 FCQG71FX2 FBQ71CX2 FHQG71CX2 FAQ71CX2 FHQ71CAX2 FBQ71DX2 FCQHG71FX2 FCQG71FX2 FBQ71CX2 FHQG71CX2 FAQ71CX2 FHQ71CAX2 FBQ71DX2Cooling 4,11 4,39 4,17 4,01 4,23 4,01 4,17Heating 4,23 4,48 4,94 4,71 4,92 4,71 4,94Triple TripleFCQG50FX3 FBQ50CX3 FHQ50CAX3 FFQ50CX3 FDXS50F9X3 FBQ50DX3 FNQ50AX3 FCQG50FX3 FBQ50CX3 FHQ50CAX3 FFQ50CX3 FDXS50F9X3 FBQ50DX3 FNQ50AX3Cooling 4,40 4,17 4,67 4,43 4,68 4,17 4,68Heating 4,48 4,94 5,67 4,39 4,61 4,94 4,61Doubletwin DoubletwinFCQG35FX4 FBQ35CX4 FHQ35CAX4 FFQ35CX4 FDXS35FX4 FBQ35DX4 FNQ35AX4 FCQG35FX4 FBQ35CX4 FHQ35CAX4 FFQ35CX4 FDXS35FX4 FBQ35DX4 FNQ35AX4Cooling 4,56 4,17 4,65 4,11 5,80 4,17 5,80Heating 4,54 4,94 5,57 4,05 6,09 4,94 6,0915x4(0.08x4)8.7x4(0.17x4)AFR(BF)12.5x4(0.4x4)16x4(0.15x4)14x4(0.20x4)10x4(0.25x4)8.7x4(0.17x4)16x3(0.11x3)15x3(0.13x3)16x3(0.11x3)20.5x2(0.13x2)18x2(0.13x2)AFR(BF)12.6x3(0.22x3)16x3(0.16x3)15x3(0.18x3)12x3(0.16x3)AFR(BF)21.2x2(0.2x2)21.5x2(0.14x2)18.0x2(0.08x2)20.5x2(0.13x2)18.0x2(0.16x2)30.0(0.18)34.0(0.17)34.0(0.06)AFR(BF)33.5(0.15)33.0(0.23)39:C/41:H(0.14)34.0(0.17)CoefficientofthepowerinputCoefficientofthepowerinputCoolingcapacity[kW] Heatingcapacity[kW]CapacityrangeRatedpointCapacityrangeRatedpointIndoorIndoorOutdoortemperature[°CDB] Outdoortemperature[°CWB]3D076755E