ESIE16-03B | Part 5. Appendix 5.3. Wiring diagramSA R32 Sky-Air RZAG-LPage 114 22/08/16 | Version 1.15.3. Wiring diagram5.3.1. Indoor unitFigure 5-1: Wiring diagram - indoor unitNotes1. In case using central remote controller, connect it to the unit in accordance with the attached installation manual.2. In case of main/sub changeover. See the installation manual attached to remote controller.3. Shows only in case of protected pipes. Use H07RN in case of no protection.4. When connecting the input wires from outside, forced off or on/off control operation can be selected by the remote controller. See installation manual for more details.5. Connect power of adapter for wiring to terminal block (X2M) of indoor unit directly.6. X35A, X39A, X70A are connected when the optional accessories are being used. In case an auto cleaning panel is used, see the wiring diagram.Legend V1R (A1P) Diode moduleA1P Main PCB X1A (A7P) Connector (power supply for option PCB)A2P Adapter PCB X2A (A7P) PCB connector (sensor kit)A3P, A4P * Sensor kit PCB X24A (A1P) PCB connector (wireless remote controller)A5P, A6P Receiver/display PCB X33A (A1P) PCB connector (adapter for wiring)A7P * Adapter for wiring X35A (A1P) PCB connector (auto clean panel)BS01 (A6P) Push button (ON/Off) X39A (A1P) PCB connector (auto clean panel)C105 (A1P) Capacitor X70A (A1P) PCB connector (auto clean panel)DS1 (A1P) DIP switch X*A PCB connectorF1U (A7P) Fuse B, 5 A 250 V X*M Terminal stripF2U (A7P) Fuse B, 5 A 250 V X*Y ConnectorHAP (A1P) Running LED (service monitor-green) Z*C Noise filter (ferrite core)H1P (A6P) LED (On-red) Z*F Noise filterH2P (A6P) LED (timer-green) * OptionalH3P (A6P) LED (filtersign-red) # Field supplyH4P (A6P) LED (defrost-orange)H5P (A6P) LED (element cleaning-red) SymbolsH6P (A6P) LED (ventilation cleaning-green) X1M Main terminalKCR (A7P) Magnetic relay Earth wiringKFR (A7P) Magnetic relay Wire number 15KHuR (A7P) Magnetic relay (Hu) Field wireK2R Magnetic relay Field cableM1F Fan motor (indoor) Connection ** continues on page 12 column 2M1P Motor (drain pump) Several wiring possibilitiesM*S Motor (swing flap) OptionPS (A1P) Power supply Not mounted in switch boxR1T Thermistor (air) Wiring depending on modelR2T Thermistor (liquid piping) PCBR3T Thermistor (coil)RC (A1P) Signal receiver circuit ColoursSS1 (A5P) Selector switch (emergency) BLK: BlackSS2 (A5P) Selector switch (wireless address set) WHT: WhiteS1L Float switch RED: RedTC (A1P) Signal transmission circuitA1PA3PA4PA7PA2PX2AF1UX1AKhUrKFRKCRX2M 1 2 321 3 4 5 6X33A X35A X20A1 2 3 4 5 613524BLKWHTRED1 2 31 2 3 4 1 2 321 21X17AX16A X83AX15A X18AX39A12PSH05VV-U4G2,5Z2C R3TS1LR2T R1Tt°t° t° 1 2 3 4HAP1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20121 2 3 5 64 7 8 9 10 1 2 3 5 64 7 8X81A X30AONOFF1 2 31234532145123456789321456789H1PH2PH3PH4PH5PH6PX70A5 81 2 21 3 6 74M M M MX36A X25AOFF ONOFF ON11M4S M3S M2S M1SN=1CN1F2U12RCTCA5P A6PM1F M1P1 2 3 41 2 3 4 5 6t°R1TY2YCX1X2X3X4NORM.EMGBS1NP4D099158-11 2X2A X1A X1AX24ASS1SS2T2 T1 F2 F1 P NDS1X27A K2R X1MC105V1RMSZ1FNEPEZ1CN=1X1Y 1 2 3 4 5MSTerminal for operation displayCompressoroperationSensor kitUser interfaceCentral remote controller (see note 1)Input from outside (see note 4)Fan operationAdapter for wiring (see note 5) Receiver / display unit(see note 6)(seenote 6)(see note 6)(see note 3)Outdoor(see note 2)