16 English12 WIRING DIAGRAMVKM50·80·100GMV13D047684-1POWER SUPPLY220-240V~50HzADAPTER PC BOARD FOR WIRING(OPTIONAL ACCESSORIES)EXTERNAL OUTPUTTERMINALSCONTACTCAPACITYNote) 6INPUT FROM OUTSIDENote) 3TO CONNECTION WIRING ANDCENTRAL REMOTECONTROLLER UNITWIRED REMOTE CONTROLLER(OPTIONAL ACCESSORIES)Note) 5INPUTFROMOUTSIDENote) 4Note) 8Note) 7Note) 7Note) 9A1PA2PA3PC1·C2F1UF1UF1U,F2UF1UT·F2UTHAPHAPK1R~K3RK4R~K6RK7RK8RKCR,KFRKHR,KHuRM1DM1FM2FR1TR2TR3TR4T,R5TS1LS1QSS1SS1T1RT2RPRINTED CIRCUIT BOARDPRINTED CIRCUIT BOARDPRINTED CIRCUIT BOARD(ADAPTOR FOR WIRING)CAPACITOR (M1F, M2F)FUSE ( B , 10A, 250V)(A1P)FUSE ( B , 5A, 250V)(A2P)FUSE ( B , 5A, 250V)(A3P)THERMO SWITCH(152˚C)(M1F, M2F BUILT-IN)LIGHT EMITTING DIODE(SERVICE MONITOR-GREEN)(A1P)LIGHT EMITTING DIODE(SERVICE MONITOR-GREEN)(A2P)MAGNETIC RELAY (M1F)(A1P)MAGNETIC RELAY (M2F)(A1P)MAGNETIC RELAY (M1D)(A1P)MAGNETIC RELAY (S1L)MAGNETIC RELAY (A3P)MAGNETIC RELAY (A3P)MOTOR (DAMPER MOTOR)MOTOR (SUPPLY AIR FAN)MOTOR (EXHAUST AIR FAN)THERMISTOR (INDOOR AIR)THERMISTOR (OUTDOOR AIR)THERMISTOR(INLET AIR INTO COIL)THERMISTOR(LIQUID/GAS PIPE OF COIL)FLOAT SWITCH (HUMIDIFIER)LIMIT SWITCH(DAMPER MOTOR)SELECTOR SWITCH(FOR ESPECIALLY USE )(A1P)SELECTOR SWITCH(HUMIDISTAT INPUT )(A3P)TRANSFORMER(220-240V/22V)TRANSFORMER(220-240V/22V)X1MX1M,X2MX2MX3MX17A,X19AX20AY1EY2STERMINAL BLOCK(POWER SUPPLY)TERMINAL BLOCK(CONTROL)(A3P)TERMINAL BLOCK(CONTROL)(A1P)TERMINAL BLOCK(CONTROL)CONNECTOR(RELAYING WIRE)CONNECTOR(RELAYING WIRE)ELECTRONIC EXPANSIONVALVEFEED WATER SOLENOIDVALVE2. : FIELD WIRING3. IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHEDINSTRUCTION MANUAL.4. IN CASE USING WIRING ADAPTER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED INSTALLATIONMANUAL.5. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FRESH UP CONTROL OPERATION CAN BE SELECTED BYREMOTE CONTROLLER, IN DETAILS, REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT.6. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED OFF OR ON/OFF CONTROL OPERATION CAN BESELECTED BY REMOTE CONTROLLER, IN DETAILS, REFER TO THE INSTALLATION MANUAL ATTACHED THE UNIT.7. IN CASE INSTALLING A HUMIDISTAT S1H (LOCALLY PROCURED), REMOVE THE SHORT CIRCUIT WIRING BETWEEN (1)AND (2) AS SHOWN IN THE FIGURE RIGHT.8. DO NOT REMOVE THE SHORT CIRCUIT CONNECTORS OF X8A AND X9A, THE UNIT WILL NOT RUN IF THEY AREREMOVED.9. SS1 (A3P) HAS ALREADY BEEN SET TO OFF AT FACTORY SET. HUMIDIFYING BECOMES IMPOSSIBLE, IF THE SETTINGARE CHANGED.10. SS1(A1P) HAS ALREADY BEEN SET TO “NOR.” AT FACTORY SET. THE UNIT WILL NOT RUN IF THE SETTING ARECHANGED.11. SYMBOLS SHOW AS FOLLOWS. (PNK: PINK WHT: WHITE YLW: YELLOW ORG: ORANGE BLU:BLUEBLK: BLACK RED: RED GRN: GREEN)12. USE COPPER CONDUCTORS ONLY.: TERMINAL BLOCK, : TERMINAL, : CONNECTOR, : SHORT CIRCUIT CONNECTOR1.Notes)OPTIONAL ACCESSORIESWIRED REMOTE CONTROLLERSS1Ry1Ry2Tes10SELECTOR SWITCH(MAIN/SUB)ADAPTOR PC BOARD FOR WIRING(KRP50-2)MAGNETIC RELAY(OPERATION/STOP)MAGNETIC RELAY(FOR HUMIDIFIER OPERATION)TERMINAL BLOCK(FOR EXTERNAL OUTPUT)CONNECTOR FOROPTIONAL PARTSLOCAL SUPPLIED PARTSX11AX18ACONNECTOR(ADAPTER POWERSUPPLY)(A1P)CONNECTOR(WIRING ADAPTER FORELECTRICAL APPENDICES)(A2P)S1H HUMIDISTAT,WIRING DIAGRAMCONTROL BOX