6M18 Camera User’s Manual 8DALSA 03-32-10017-03CalibrationConditionsUnits Setting Min. Max. NotesData Rate MHz 4x40 4x40 4x40+15 Input Voltage V +15 +14.925 +15.075 2+5 Input Voltage V +5 +4.975 +5.025 2-5 Input Voltage V - 5 - 4.975 - 5.025 2Binning Mode 1x1AmbientTemperature°C 25Gain X 1xElectro-OpticalSpecificationsUnits Min. Typical Max. NotesQuantum Efficiency@ 530nm% 20 26Dark CurrentGeneration @ 30Ce- /pix/sec 305Dark Offset DN 40 50 60Dynamic Range 1850:1 2500:1System Noise DN(rms) 1.5 2.0Saturation OutputAmplitudeDN 3700 3800Maximum Full frameRateFps 18Integration time atMax Frame RatemSec 1.4FPN DN(rms) 1.5 2.0 3PRNU % 0.5 5 4Responsivity @530nmDN/(nj/cm2) 32 36 41Notes:Notes:Notes:Notes:1. Each of the 60 Pin Molex connectors contains 2 12 bit data words synchronizedto 1 set of control signals.2. Max supply ripple for Performance specs <5mV3. FPN = Fixed Pattern Noise defined by the following equation:FPN(DNrms)=Std_dev(Dark_image(i,j))Dark_image(i,j)= pixel by pixel average of a statistically significant number of data frames indarknessStd_dev= Standard deviation4. PRNU= Photo Response Nonuniformity defined by the following equation:PRNU(%) = [Std_dev (illuminated_50(i,j)) / (mean(Illuminated_sat(i,j))-mean(Dark_average(i,j)))] x 100illuminated_50(i,j)= pixel by pixel average image of a statistically significant number ofimages at 50% illuminationilluminated_sat(i,j)= pixel by pixel average image a statistically significant number ofsaturated frames