Piranha ES-xx User ManualTeledyne DALSA 03-032-20070-0289Appendix AError Handling andCommand ListA1 Error HandlingThe follow ing table lists w arning and error m essages and provid es a d escription andpossible cau se. Warning m essages are retu rned w hen the cam era cannot m eet the fu llvalu e of the requ est; error m essages are retu rned w hen the cam era is u nable to com pletethe requ est.Table 21: Warning and Error MessagesWarning MessagesCamera Response CommentOK> Camera executed commandWarning 01: Outsid e of specification> Parameter accepted w as outsid e of specifiedoperating range (e.g. gain greater than ±10 d B offactory setting, or SSF below specification ).Warning 02: Clipped to min> Parameter w as clipped to the current operatingrange. Use GCP or GET to see value used .Warning 03: Clipped to max> Parameter w as clipped to the current operatingrange. Use GCP or GET to see value used .Warning 04: Related parametersad justed >Internal operating cond ition is ad justed toaccommod ate the entered command . E.g.requesting exposure time longer than line timeautomatically ad justs the line time to meet theexposure time requirement.Warning 07: Coefficient may beinaccurate A/ D clipping has occurred >In the region of interest (ROI) greater than 6.251%single or 1% of averaged pixel values w ere zero orsaturated .Warning 08: Greater than 1% ofcoefficients have been clippedGreater than 1% of FPN or PRN U coefficients havebeen calculated to be greater than the maximumallow able and so w ere clipped .Warning 09: Internal line rateinconsistent w ith read out time>Changing this parameter (e.g. vertical binning) haschanged read out time and that is greater than theinternal SYN C