Piranha ES-xx User Manual03-032-20070-02 Teledyne DALSA90Error MessagesCamera Response CommentError 01: Internal error xx> Where xx is a cod e list below .Only output d uring pow er up.Customer should contact customer support.Error 02: Unrecognized command > Command is not valid .Error 03: Incorrect number ofparameters>Too many or too few parameters.Error 04: Incorrect parameter value> This response returned for Alpha received for nu m eric or visa versa Float w here integer expected N ot an elem ent of the set of possible valu es.E.g., Bau d Rate Ou tsid e the range lim itError 05: Command unavailable inthis mod e>E.g. SSF w hen in SEM 3Error 06: Timeout> Command not completed in time. E.g. CCF or CCP inSEM 3 w hen no external EXSYN C is present.Error 07: Camera settings not saved > Ind icates that user settings have been corrupted byturning off the pow er w hile executing the WUScommand . Must build up new settings from factoryand re-save w ith WUS.Error 08: Unable to calibrate - tapoutsid e ROI>Cannot calibrate a tap that is not part of the end of linestatistics.Error 09: The camera's temperatureexceed s the specified operatingrange>Ind icates that the camera has shut itself d ow n toprevent d amage from further overheating. (flashingred )Shuts d ow n at internal temperature of 75˚C and w illnot restart until below 65˚C (equivalent to 50˚C at frontplate).Error 10: FPGA Flash Program Failed FCS failed either because of communication error or abad file w as sent.