68 • Technical Specifications X64 Xcelera-HS PX8 User's ManualJ2 HS-Link Input / J3 HS-Link Output ConnectorsFor the HS-Link connectors, pin-outs are not provided. Camera connections should be made withmanufactured cables such as recommended by Teledyne DALSA (see Product Part Numbers).HS-Link Camera Control Signal OverviewThere are four general-purpose camera controls available.• Camera Control 1 (CC1)• Camera Control 2 (CC2)• Camera Control 3 (CC3)• Camera Control 4 (CC4)Each camera manufacture is free to define the signals input on any one or all four control signals.These control signals are used either as camera control pulses or as a static logic state. Controlsignals not required by the camera are simply assigned as not used. Refer to your camera's usermanual for information on what control signals are required.Note: The X64 Xcelera-HS PX8 pulse controller has a minimum resolution of 100ns for line triggersignals (applies to linescan cameras), and resolution of 1μs for all other signal. When configuringthe Camera Link control signals such as exposure control, etc. use values in increments of 1 μs.The X64 Xcelera-HS PX8 can assign any camera control signal to the appropriate HS-Link control.The following screen shot shows the Sapera CamExpert dialog where Camera Link controls areassigned.Figure 28: CamExpert - Camera Link Controls