31MG.60.N1.22 - VLT is a registered Danfoss trademarkVLT® 5000 / VLT® 6000 HVAC / VLT® 8000 AQUABit Value 0 1 Bit Value 0 100 32768 33 OFF 33 ON 00 3276801 16384 32 OFF 32 ON 01 1638402 8192 29 OFF 29 ON 02 819203 4096 27 OFF 27 ON 03 409604 2048 19 OFF 19 ON 04 204805 1024 18 OFF 18 ON 05 102406 512 17 OFF 17 ON 06 51207 256 16 OFF 16 ON 07 25608 128 no function 08 12809 64 no function 09 6410 32 no function 10 3211 16 no function 11 1612 8 no function 12 813 4 no function 13 4 Stopped Running14 2 no function 14 2 No Warning Warning15 1 no function 15 1 no Alarm AlarmBit Value 0 1 Bit Value 0 100 32768 Alarm Ctrl. Ready 00 32768 normal Unknown Fault01 16384 Alarm Drive Ready 01 16384 normal Trip Lock02 8192 Safety Open Safety Closed 02 8192 normal AMA Fault03 4096 No Alarm Alarm 03 4096 normal HPFB Timeout04 2048 04 2048 normal RS-485 Timeout05 1024 05 1024 normal ASIC Fault06 512 06 512 normal Short circuit07 256 no Warning Warning 07 256 normal SMPS Fault08 128 Not at Ref. at Ref. 08 128 normal Ground Fault09 64 Hand Mode Auto Mode 09 64 normal Overcurrent10 32 Fr. Range Warn Freq. in Range 10 32 normal Current limit11 16 Stopped Running 11 16 normal Mtr. Thermistor12 8 no used 12 8 normal Motor thermal13 4 normal Voltage Warn. 13 4 normal Undervoltage14 2 normal Current lim. 14 2 normal Overvoltage15 1 normal Therm. Warning 15 1 normal In. Phase lossBit Value 0 1 Bit Value 0 100 32768 normal Ref. High 00 32768 normal Autoramping01 16384 normal Ctrl. Crd. Fault 01 16384 normal Start Delay02 8192 normal Pwr. Crd. Fault 02 8192 normal Sleep Boost03 4096 normal HPFB Timeout 03 4096 normal Sleep04 2048 normal RS-485 Timeout 04 2048 normal AMA Done05 1024 normal Overcurrent 05 1024 normal AMA Running06 512 normal Current limit 06 512 normal Rev. Start07 256 normal Thermistor O.T. 07 256 no Ramp Ramping08 128 normal Motor O.T. 08 128 Forward Reverse09 64 normal Inverter O.T. 09 64 not at Ref. at Reference10 32 normal U.V. Alarm 10 32 Stopped Running11 16 normal O.V. Alarm 11 16 Remote Ref. Local Ref.12 8 normal U.V. Warning 12 8 normal OFF (HOA)13 4 normal O.V. Warning 13 4 Auto Start/stop Hand14 2 normal Input Phase Loss 14 2 normal Run Request15 1 normal Live Zero 15 1 Run Permission no Run Perm.no functionnot usednot usednot usedno functionno functionno functionno functionno functionno functionno functionno functionno functionno functionno functionno functionVLT 6000/8000Drive Status BitDefinitionsnvoWarning1 nvoWarning2nvoStatusWord nvoAlarmWordnvoDigitalInput nvoDrvStatus