Normal overload 110% for 1 minuteFrequency converterTypical Shaft Output [kW]P110110P132132P160160P200200P250250P315315P355355P400400P500500P560560Typical Shaft Output [HP] at 575 V 150 200 250 300 350 400 450 500 600 650IP 00 D3 D3 D4 D4 D4 D4 E2 E2 E2 E2IP 21 D1 D1 D2 D2 D2 D2 E1 E1 E1 E1IP 54 D1 D1 D2 D2 D2 D2 E1 E1 E1 E1Output currentContinuous (3 x 550 V) [A] 162 201 253 303 360 418 470 523 596 630Intermittent (3 x 550 V) [A] 178 221 278 333 396 460 517 575 656 693Continuous (3 x 575-690V) [A] 155 192 242 290 344 400 450 500 570 630Intermittent (3 x 575-690 V) [A] 171 211 266 319 378 440 495 550 627 693Continuous kVA (550 V AC) [kVA] 154 191 241 289 343 398 448 498 568 600Continuous kVA (575 V AC) [kVA] 154 191 241 289 343 398 448 498 568 627Continuous kVA (690 V AC) [kVA] 185 229 289 347 411 478 538 598 681 753Max. cable size:(mains, motor, brake) [mm 2 / AWG] 2) 2x702x2/02x1852x350 mcm4x2404x500 mcmMax. input currentContinuous (3 x 550 V) [A] 158 198 245 299 355 408 453 504 574 607Continuous (3 x 575 V) [A] 151 189 234 286 339 390 434 482 549 607Continuous (3 x 690 V) [A] 155 197 240 296 352 400 434 482 549 607Max. pre-fuses 1)[A] 225 250 350 400 500 600 700 700 900 900EnvironmentEstimated power lossat rated max. load [W] 4) 3114 3612 4293 5156 5821 6149 6449 7249 8727 9673Weight enclosure IP00 [kg] 81.9 90.5 111.8 122.9 137.7 151.3 221 221 236 277Weight enclosure IP 21 [kg] 95.5 104.1 125.4 136.3 151.3 164.9 263 263 272 313Weight enclosure IP 54 [kg] 95.5 104.1 125.4 136.3 151.3 164.9 263 263 272 313Efficiency 3) 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.981) For type of fuse see sectionFuses2) American Wire Gauge3) Measured using 5 m screened motor cables at rated load and rated frequency4) The typical power loss is at normal load conditions and expected to be within +/- 15% (tolerance relates to variety in voltage and cable conditions).Values are based on a typical motor efficiency (eff2/eff3 border line). Lower efficiency motors will also add to the power loss in the frequency converter and vice versa.If the switching frequency is raised from nominal the power losses may rise significantly.LCP and typical control card power consumptions are included. Further options and customer load may add up to 30W to the losses. (Though typically only 4W extra for a fully loaded control card, or options for slot A or slot B,each).Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (+/- 5%).3. VLT AQUA Selection VLT® AQUA Drive Design Guide46 MG.20.N3.02 - VLT® is a registered Danfoss trademark3