Type designation P5K5 P7K5 P11K P15KHigh/normal overload1) HO NO HO NO HO NO HO NOTypical shaft output [kW] 3.7 5.5 5.5 7.5 7.5 11 11 15Typical shaft output at 208 V [hp] 5.0 7.5 7.5 10 10 15 15 20IP20/Chassis7) B3 B3 B3 B4Protection rating IP21/Type 1Protection rating IP55/Type 12Protection rating IP66/NEMA 4XB1 B1 B1 B2Output currentContinuous (3x200–240 V) [A] 16.7 24.2 24.2 30.8 30.8 46.2 46.2 59.4Intermittent (3x200–240 V) [A] 26.7 26.6 38.7 33.9 49.3 50.8 73.9 65.3Continuous kVA at 208 V [kVA] 6.0 8.7 8.7 11.1 11.1 16.6 16.6 21.4Maximum input currentContinuous (3x200–240 V) [A] 15.0 22.0 22.0 28.0 28.0 42.0 42.0 54.0Intermittent (3x200–240 V) [A] 24.0 24.2 35.2 30.8 44.8 46.2 67.2 59.4Maximum pre-fuses [A] 63 63 63 80Additional specificationsIP20 maximum cable cross-section2) for mains, brake,motor, and load sharing [mm2] ([AWG]) 10, 10, - (8, 8, -) 10, 10, - (8, 8, -) 10, 10, - (8, 8, -) 35, -, - (2, -, -)Protection rating IP21 maximum cable cross-section2)for mains, brake, and load sharing [mm2] ([AWG]) 16, 10, 16 (6, 8, 6) 16, 10, 16 (6, 8, 6) 16, 10, 16 (6, 8, 6) 35, -, - (2, -, -)Protection rating IP21 maximum cable cross-section2)for motor[mm2] ([AWG])10, 10, - (8, 8, -) 10, 10, - (8, 8, -) 10, 10, - (8, 8, -) 35, 25, 25 (2, 4, 4)Maximum cable cross-section2) for mains disconnect[mm2] ([AWG]) 16, 10, 10 (6, 8, 8) 35 (2)Estimated power loss3) at rated maximum load [W]4) 239 310 239 310 371 514 463 602Efficiency5) 0.96 0.96 0.96 0.96Table 7.4 Mains Supply 3x200–240 V AC, P5K5–P15KSpecifications Design GuideMG20N602 Danfoss A/S © 09/2014 All rights reserved. 1377 7