Control card, 10 V DC outputTerminal number 50Output voltage 10.5 V ±0.5 VMaximum load 25 mA7.8 Connection Tightening TorquesLocation Type Torque[Nm (in-lb)]Front cover screws T20 or slot 3–3.5 (26.6–31)Plastic cable blind plugs 24 mm or 28 mm socket 2.2 (19.5)Control card T10 1.3 (11.5)Relay card T10 1.3 (11.5)Control plate T20 or slot 1.5 (13.3)Connection to adapter plate T20 or slot 7.0 (62)Table 7.12 Tightening Torques for Frequency Converter External ScrewsEnclosure sizePower1)[kW (hp)]Torque[Nm (in-lb)]3x380–480 V Mains Motor DCconnectionControlterminalsGround Relay RFI switchMH1 0.55–1.5 (0.75–2.0) 1.4 (12.4)Crimp,no appliedtorque1.4 (12.4) 0.5 (4.4) 3.0 (26.6) 0.5 (4.4) 0.9 (8.0)MH2 2.2–4 (3.0–5.0)MH3 5.5–7.5 (7.5–10)Table 7.13 Tightening Torques for Frequency Converter Internal Screws1) Power ratings relate to NO, see chapter 7.2 Electrical Data.Enclosure sizePower1)[kW (hp)]Type3x380–480 V Mains Motor DCconnectionControlterminalsGround Relay RFI switchMH1 0.55–1.5 (0.75–2.0) Slot orPhillips Crimp Slot orPhillipsSlot orPhillipsT20,slot, or10 mm socketSlot T20 orslotMH2 2.2–4 (3.0–5.0)MH3 5.5–7.5 (7.5–10)Table 7.14 Screw Types for Frequency Converter Internal Screws1) Power ratings relate to NO, see chapter 7.2 Electrical Data.7.9 FCM 106 Motor SpecificationsMotor output (U, V, W)Output voltage 0–100% of supply voltageOutput frequency, asynchronous motor 0–200 Hz (VVC+), 0–400 Hz (u/f )Output frequency, PM motor 0–390 Hz (VVC+ PM)Switching on output UnlimitedRamp times 0.05–3600 sThermistor input (at motor connector)Input conditions Fault: >2.9 kΩ, no fault: <800 ΩSpecifications Operating InstructionsMG03L302 Danfoss A/S © 11/2015 All rights reserved. 517 7