9.3.5 14-** Special FunctionsPar.No. #Parameter description Default value 4-set-up ChangeduringoperationConver-sion indexType14-2* Trip Reset14-20 Reset mode [0] Manual reset All set-ups TRUE - Uint814-21 Automatic restart time 10 s All set-ups TRUE 0 Uint1614-22 Operation mode [0] Normal operation All set-ups TRUE - Uint814-23 Typecode setting null 2 set-ups FALSE - Uint814-28 Production settings [0] No action All set-ups TRUE - Uint814-29 Service code 0 N/A All set-ups TRUE 0 Int3214-5* Environment14-50 RFI filter [1] On 1 set-up FALSE - Uint814-53 Fan monitor [1] Warning All set-ups TRUE - Uint814-54 Bus partner 1 N/A 2 set-ups TRUE 0 Uint169.3.6 15-** FC InformationPar.No. #Parameter description Default value 4-set-up ChangeduringoperationConver-sion indexType15-0* Operating Data15-00 Operating hours 0 h All set-ups FALSE 74 Uint3215-01 Running hours 0 h All set-ups FALSE 74 Uint3215-03 Power up's 0 N/A All set-ups FALSE 0 Uint3215-04 Over temp's 0 N/A All set-ups FALSE 0 Uint1615-05 Over volt's 0 N/A All set-ups FALSE 0 Uint1615-07 Reset running hours counter [0] Do not reset All set-ups TRUE - Uint815-1* Data Log Settings15-10 Logging source 0 2 set-ups TRUE - Uint1615-11 Logging interval ExpressionLimit 2 set-ups TRUE -3 TimD15-12 Trigger event [0] False 1 set-up TRUE - Uint815-13 Logging mode [0] Log always 2 set-ups TRUE - Uint815-14 Samples before trigger 50 N/A 2 set-ups TRUE 0 Uint815-2* Historic Log15-20 Historic log: Event 0 N/A All set-ups FALSE 0 Uint815-21 Historic log: Value 0 N/A All set-ups FALSE 0 Uint3215-22 Historic log: Time 0 ms All set-ups FALSE -3 Uint3215-3* Fault Log15-30 Fault log: Error code 0 N/A All set-ups FALSE 0 Uint1615-31 Fault log: Value 0 N/A All set-ups FALSE 0 Int1615-32 Fault log: Time 0 s All set-ups FALSE 0 Uint3215-4* Unit Identification15-40 FC type 0 N/A All set-ups FALSE 0 VisStr[6]15-41 Power section 0 N/A All set-ups FALSE 0 VisStr[20]15-42 Voltage 0 N/A All set-ups FALSE 0 VisStr[20]15-43 Software version 0 N/A All set-ups FALSE 0 VisStr[5]15-44 Ordered typecode string 0 N/A All set-ups FALSE 0 VisStr[40]15-45 Actual typecode string 0 N/A All set-ups FALSE 0 VisStr[40]15-46 Unit ordering number 0 N/A All set-ups FALSE 0 VisStr[8]15-47 Power card ordering number 0 N/A All set-ups FALSE 0 VisStr[8]15-48 LCP ID number 0 N/A All set-ups FALSE 0 VisStr[20]15-49 SW ID control card 0 N/A All set-ups FALSE 0 VisStr[20]Appendix A - Parameters VLT® HVAC Drive FC 102 Low Harmonic Drive108 Danfoss A/S © 04/2015 All rights reserved. MG16I30299