MCT Set-up 10 SoftwareSetting parametersCopy to and from frequency convertersDocumentation and print of parameter settingsincl. diagramsExt. user interfacePreventive Maintenance ScheduleClock settingsTimed Action ProgrammingSmart Logic Controller Set-upTable 5.1Ordering number:Order the CD containing MCT 10 Set-up Software usingcode number 130B1000.The software can be downloaded from the Danfossinternet site www.Danfoss.com/BusinessAreas/DrivesSo-lutions/Softwaredownload/DDPC+Software+Program.htm5.1.6 Tips and Tricks• For most HVAC applications the Quick Menu,Quick Set-up and Function Set-up provides thesimplest and quickest access to all the typicalparameters required• Whenever possible, performing an AMA, ensuresbest shaft performance• Contrast of the display can be adjusted bypressing [Status] and [▲] for darker display or bypressing [Status] and [▼] for brighter display• Under [Quick Menu] and [Changes Made] allparameters that have been changed from factorysettings are displayed• Press and hold [Main Menu] key for 3 s for accessto any parameter• For service purposes, copy all parameters to theLCP, see 0-50 LCP Copy for further information5.1.7 Quick Transfer of Parameter Settingswhen Using GLCPOnce the set-up of a frequency converter is complete,store (back up) the parameter settings in the GLCP or on aPC via MCT 10 Set-up Software.WARNINGStop the motor before performing any of theseoperations.Data storage in LCP1. Go to 0-50 LCP Copy.2. Press [OK].3. Select [1] All to LCP.4. Press [OK].All parameter settings are now stored in the GLCPindicated by the progress bar. When 100% is reached,press [OK].The GLCP can now be connected to another frequencyconverter and the parameter settings copied to thisfrequency converter.Data transfer from LCP to frequency converter1. Go to 0-50 LCP Copy.2. Press [OK].3. Select [2] All from LCP.4. Press [OK]The parameter settings stored in the GLCP are nowtransferred to the frequency converter indicated by theprogress bar. When 100% is reached, press [OK].5.1.8 Initialisation to Default SettingsThere are 2 ways to initialise the frequency converter todefault: Recommended initialisation and manual initiali-sation.Be aware that they have different impact according to thefollowing description.Recommended initialisation (via 14-22 Operation Mode)1. Select 14-22 Operation Mode.2. Press [OK].3. Select [2] Initialisation (for NLCP select “2”).4. Press [OK].5. Remove power to unit and wait for display toturn off.6. Reconnect power and the frequency converter isreset. Note that first start-up takes a few moreseconds.7. Press [Reset]14-22 Operation Mode initialises all except:14-50 RFI Filter8-30 Protocol8-31 Address8-32 Baud Rate8-35 Minimum Response Delay8-36 Max Response Delay8-37 Maximum Inter-Char Delay15-00 Operating hours to 15-05 Over Volt'sHow to Operate the Frequenc... Operating Instructions56 Danfoss A/S © Rev. 06/2014 All rights reserved. MG16B20255 PreviousNext |