6.3 Installation ProcedureWARNINGHIGH VOLTAGE!The power supply module contains high voltage whenconnected to AC mains input power. Installation, start up,and maintenance should be performed by qualifiedpersonnel only. Failure to perform installation, start up, andmaintenance by qualified personnel could result in deathor serious injury.WARNINGINCORRECT VOLTAGE!Connecting the incorrect voltage to the power supplymodule can result in death or serious injury and damageto the unit.• Only connect voltages of AC 400-480 V, 50/60 Hz,3-phase and PE.• Only TN mains are allowed.1. Wire and connect the power input plug to “AC-In:-X1”PEAC-InL1 L3L2130BD043.10Illustration 6.2 Power Input Plug2. Wire and connect the power output plug to “DC-Out: -X2”130BD044.10PE+Uo.1 +Uo.2 -Uo.1 -Uo.2Illustration 6.3 Power Output Plug3. Wire and connect the signal plug to “Signals: -X3”to enable the hardware.The pin assignment is detailed in chapter8.7.3 Signal Connection X3.1 2 3 4 5 6 7 8 9 10 11 12 13 14130BD045.10Illustration 6.4 Signal Plug4. Wire and connect the CAN bus plug to “CAN: -X4”CAN-GNDCAN_L (NC) CAN_H(CAN+5V)130BD046.10Illustration 6.5 CAN Bus Plug5. Ensure that the CAN dip switch is set to“500 kbit/s” (default)----onon1 2 3 4onon--onon--ononCAN Node-IdCAN Bit Rate0x78 *)0x790x7A0x7B125 kbit/s250 kbit/s500 kbit/s *)1 Mbit/sCAN-Reset Button*) = default130BD047.10Illustration 6.6 CAN Dip SwitchElectrical Installation VLT® ISD Power Supply Module Operating Instructions16 MG75H102 - VLT® is a registered Danfoss trademark66