7.4.3 Parameter List1 Primary Mtr Set 4 Outputs 7-11 Stop Time-21-1 Motor FLC 4-1 Relay A Function 7-12 Adaptv Ctrl Gain-21-2 Locked Rotor Time 4-2 Relay A On Delay 7-13 Adaptv Start Prof-21-3 Start Mode 4-3 Relay A Off Delay 7-14 Adaptv Stop Prof-21-4 Current Limit 4-4 Relay B Function 7-15 Brake Torque-21-5 Initial Current 4-5 Relay B On Delay 7-16 Brake Time-21-6 Start Ramp Time 4-6 Relay B Off Delay 8 Display1-7 Kickstart Level 4-7 Relay C Function 8-1 Language1-8 Kickstart Time 4-8 Relay C On Delay 8-2 User Scrn Top L1-9 Excess Start Time 4-9 Relay C Off Delay 8-3 User Scrn Top R1-10 Stop Mode 4-10 Low Current Flag 8-4 User Scrn Btm L1-11 Stop Time 4-11 High Current FLag 8-5 User Scrn Btm R1-12 Adaptv Control Gain 4-12 Motor Temp Flag 8-6 Graph Timebase1-13 Adaptv Start Profile 4-13 Analog Output A 8-7 Graph Max Adj1-14 Adaptv Stop Profile 4-14 Analog A Scale 8-8 Graph Min Adj1-15 Brake Torque 4-15 Analog A Max Adj 8-9 Mains Ref Volt1-16 Brake Time 4-16 Analog A Min Adj 15 Restrict Paramtr2 Protection 5 Start/Stop Timers 15-1 Access Code2-1 Phase Sequence 5-1 Auto-Start Type 15-2 Adjustment Lock2-2 Current Imbalance 5-2 Auto-Start Time 15-3 Emergency Run2-3 Current Imbal Dly 5-3 Auto-Stop Type 15-4 Current Calibrat2-4 Undercurrent 5-4 Auto-Stop Time 15-5 Main Cont Time2-5 Undercurrent Dly 6 Auto-Reset 15-6 Bypass Cont Time2-6 Inst Overcurrent 6-1 Auto-Reset Action 15-7 Motor Connection2-7 Inst Ocrnt Dly 6-2 Maximum Resets 15-8 Jog Torque2-8 Frequency Check 6-3 Reset Dly Grp A & B 16 Protection Action2-9 Freq Variation 6-4 Reset Delay Grp C 16-1 Motor Overload2-10 Frequency Delay 7 Secondary Mtr Set 16-2 Current Imbalance2-11 Restart Delay 7-1 Motor FLC-2 16-3 Undercurrent2-12 Motor Temp Check 7-2 Lock Rotor Time-2 16-4 Inst Overcurrent3 Inputs 7-3 Start Mode-2 16-5 Frequency3-1 Local/Remote 7-4 Current Limit-2 16-6 Heatsink Overtemp3-2 Comms in Remote 7-5 Initial Crnt-2 16-7 Excess Start Time3-3 Input A Function 7-6 Start Ramp-2 16-8 Input A Trip3-4 Input A Name 7-7 Kickstart Lvl-2 16-9 Motor Thermistor3-5 Input A Trip 7-8 Kickstart Time-2 16-10 Starter Comms3-6 Input A Trip Dly 7-9 Excess Strt Time-2 16-11 Network Comms3-7 Input A Initial Dly 7-10 Stop Mode-2 16-12 Battery/Clock3-8 Remote Reset Logic7.5 Primary Motor SettingsNB!Default settings are marked with *.The parameters in Primary Motors Settings configure the soft starter to match the connected motor. These parameters describe the motor's operatingcharacteristics and allow the soft starter to model the motor's temperature.MCD 500 Operating Instruction 7 ProgrammingMG.17.K2.02 - VLT® is a registered Danfoss trademark 597