Manual Datafox ZK-Box V4 page 47 date: 16.01.2018 Version: 04.03.06.XXIDZMTMRefLocationRefActionPINGeneralReader1IDRefGroupRefTimeRefTimenoPinLocation3IDWeekdaysTimeStartTimeEndTime4DayRefGroupRefTimeHoliday5IDGroupPINMenaceActiveStartActiveEndActiveGeneralIdentification2RefReaderPortInRefActionRefTimeEvent6IDRefReaderPortOutElapseRefTimeAction75.7. connection and wirering of the accesscontrol5.7.1. Configuration of Access control adn stucktureThe basis of the access control II are tables. They store all information about the hardware configu-ration of the access control system, access right of the employees, periods of time (activation,blocking times, holidays,...). The tables are connected as follows:The tables are created as text files. For an easier administration you can add comments within thefiles.When adding comments, you have to notice that in a comment line no field values can be given andthat the comment line has to start with a semicolon.The table Reader.txt might look like this:ID ZM TM RefLocation RefAction PinGeneral1 1 320 0 1 02 1 000 1 2 03 1 010 2 3 0