C-BOX 300/31022.9 SPECIAL NOTES FOR MATRIX READER SETUPCAUTIONWhen connected to a C-BOX 3x0 through the 25-pin connector, the9-pin Auxiliary port connector on the Matrix reader cannot be usedfor communication (i.e. configuration through VisiSet™). The Matrixreader can only be configured through the 9-pin connector insidethe C-BOX 3x0 and the C-BOX 3x0 must first be configured. seethe following paragraphs for details.2.9.1 Preparing C-Box 3x0 for Matrix Reader CommunicationThis paragraph describes how to configure a C-BOX 3x0 so that a Matrix reader cancommunicate through the C-Box3x0 and also be configured through its AuxiliaryRS232 interface.1. Open the C-BOX 3x0;2. Move the Configuration Switch from the Normal Operation to the CFG position;3. Connect the 9-pin internal connector of the C-BOX 3x0 to the PC (using acrossover cable) and run the Winhost™ configuration tool;4. Select the Connect option to open communications with the C-BOX 3X0 andwait until the correct communication speed has been determined;5. From the SCANNER INTERFACE menu, set Auto Connect: Disabled and verifyData Source: Main Interface and save the configuration to the C-Box 3x0 (referto Figure 17);Figure 17 – WinHost Configuration Menu for C-Box 3x06. Return the Configuration Switch to the Normal Operation position.22