INSTALLATION 22.4 ELECTRICAL CONNECTIONS AND HARDWARE SETUPThe following figure shows the typical layout.SCANNERAUXILIARYINTERFACEC-BOX 150SCANNERSCANNER CONFIGURATION PCSYSTEM CABLESFigure 5 – System LayoutA PC can be connected to the C-BOX 150 (and consequently to the scanner auxiliaryinterface) through the internal 9-pin connector. This allows both scannerconfiguration and monitoring of the data transmitted by the scanner (see the scannerReference Manual for more details).The scanner auxiliary interface signals are also available on the internal spring clampconnectors.The scanner configuration and data monitoring are possible once the warning LED isturned OFF.The internal 9-pin connector can also be used to configure the C-BOX 150 with a PC,through the WinHost utility.After making system cabling and switch settings, connect the scanner to the 25-pinconnector on the left side of the C-BOX 150 housing.Switch ON the C-BOX 150 power switch (see Figure 6).By default, after power on, an automatic connection procedure takes place betweenthe C-BOX 150 and the scanner. During this phase, requiring a few seconds, thewarning LED is turned ON. Once the procedure had been completed successfully,the warning LED is turned OFF.To disable this automatic connection procedure, refer to WinHost Help Online.7