Motion TestProduct Reference Guide 5-3• Lead/Wire or Paper Seal (as required by law).Motion TestThis test verifies that the scale will not ‘zero’ when the weighing surface ofthe scanner/scale is in motion.1. Verify that the Yellow LED1 is on and the Remote Display reads0.00 pounds or 0.000 kilograms.2. Press lightly on the weigh platter of the scanner/scale with one handand at the same time press and release the Zero Push Button on theoperator’s panel. The Yellow LED should turn Off and the RemoteDisplay should not display 0.00 pounds or 0.000 kilograms.3. Remove your hand from the weighing platform and verify that theYellow LED is On and the Remote Display reads 0.00 pounds or0.000 kilograms.Automatic Zero Tracking TestThis test verifies that the scanner/scale automatic zero tracking mecha-nism is operating correctly.1. Place 0.006 pounds (3 grams for metric) on the center of the weigh-ing platform. The entire weight must be placed on the weighingplatform at once for this test to be valid. The Yellow LED should goOff and the Remote Display should read 0.01 pounds (0.005 kilo-grams).1. Yellow LED indications can be configured via feature programming and may not be enabled forcertain functions.NOTEThe scanner/scale has an adaptive zero capture mechanism that re-zeros thescale over time if there is a slow change in the zero level; thus if all the weightis not placed on the weighing surface at one time, the Yellow LED will remainOn and the Remote Display will read 0.00 pounds (0.000 kilograms). When theweight is removed, the Yellow LED will turn off and the display will show aminus sign . Press the Zero Push Button to re-zero the scale.. lb