Remote Scale Display Placement/InstallationProduct Reference Guide 2-31Remote Display CablingYour installation should also take into account the routing of Remote Dis-play cabling. Ensure that distance and obstacles spanned by the routedcable will not kink, pinch or stretch it. Also keep in mind you may need todrill a hole through which to route it.Placing and Installing the Remote Scale DisplayReference Figure 2-24 while performing these procedures.1. Determine where you want to install the Remote Scale Displaybased on your counter design, the viewing angle, lighting consider-ations and cable routing discussed previously. Reference Figure 2-22 for the display’s physical dimensions. Optimally, the display(s)should be approximately eye level to the viewer(s).2. Use the template provided in Figure 2-25 to mark locations of themounting screw and cable routing holes. The mounting screw holesare on 3-1/2” (85.1 mm) centers. The cable can either be routedthrough a 3 /4” (19 mm) diameter hole directly under the mountingbase or through the cutout in the back of the base (see Figure 2-24).3. Drill the mounting screw holes using a drill bit of the appropriatediameter for your mounting screws or bolts.4. Drill the cable routing hole using a 3 /4” (19 mm) drill bit(optional).NOTEThe Remote Scale Display connector end may be secured with a rubber bandduring shipping to prevent damage to the “locking tabs” (see Figure 2-24).After routing the cable, remove this rubber band before connecting. Failure toremove the band will keep the connector from latching properly.