Contents - Table Of Contents
- Table Of Contents
- System Factory Setup
- Hardware Components
- Turning Off the System
- Processor Specifications
- Setting Up the System
- Top Panel Connections
- Front Panel Connections
- Rear View
- Status Lights
- Preventive Maintenance
- Chapter 2: Basic Hardware Components Processor Views and Dimensions
- Processor Installation
- Power Supply Connection
- Grounding Concepts
- USB Hardware Key
- CFast Card
- Battery
- Chapter 3: M-Series and E-Series Cameras Introduction
- M1xx and E1xx Camera Dimensions
- M2xx Camera Dimensions
- M3xx Camera Dimensions
- M565/M570/M575/M580 Camera Dimensions
- M6xx Camera Dimensions
- Connecting the Camera
- M2xx and M3xx Camera Connection
- M565/M570/M575/M580 Camera Connection
- M6xx Camera Connection
- Third-party Cameras
- JAI Cameras
- Basler Cameras
- Basler Line Scan Camera
- Baumer Cameras
- Smartek Cameras
- SVS-Vistek Cameras (non-IP67 rated)
- SVS-Vistek Cameras (IP67 rated)
- Camera Specifications
- E151, E151C
- E181, E181C
- E182, E182C
- E193, E193C
- E198, E198C
- M-Series
- M150, M150C
- M180, M180C
- M190, M190C
- M195, M195C
- M197, M197C
- M2xx, M2xx-RA, M2xxC, M2xxC-RA
- M210 line
- M230 line
- M270 line
- M290 line
- M565/M570/M575/M580 Camera
- M570 camera
- M6xx, M6xxC
- M610 and M610C
- M650 and M650C
- M680 and M680C
- Processor Inputs
- Processor Outputs
- Output Wiring
- Ethernet
- Serial Port
- Camera Cable
|
Connecting the Camera MX-E Series Hardware GuideDatalogic S.r.l. 32Connecting the CameraWARNING: Never wire M1xx or E1xx Camera Strobe Outputs in parallel with M1xx, E1xx, M2xx, or M3xx CameraStrobe Outputs. This will damage the cameras.M1xx and E1xx Camera ConnectionTo connect M1xx and E1xx camera trigger signals and strobe outputs, use cable 606-0674-xx (6pin Hirose Male to DB9) with terminal block 661-0399.NOTE 1: If Camera Trigger In requires a sinking signal, set the Software Trigger Event to Rising Edge. If it requires asourcing signal, set the Software Trigger Event to Falling Edge.NOTE 2: If Strobe Trigger Output requires a sinking signal, set the Strobe Trigger Output to Falling Edge. If it requires asourcing signal, set the Strobe Trigger Output to Rising Edge.NOTE 3: Disconnecting the camera will turn on some strobe lights.Terminal Name Signal NotesOptional CameraPowerDO NOT USE Do NOT apply power to this terminal ifpower is supplied by Power overEthernet (PoE ; enable/disable inVPM-Settings )Optional CameraPower GroundDO NOT USE Not required if ground is supplied byPower Over Ethernet (PoE; enable/disablein VPM-Settings )I/O Ground I/O GroundTrigger In** Camera Trigger In 0 to +24 VDC recommendedMaximum +30 VDCAs sinking inputOff: 0 to +1.4 VDCOn: +2.2 to +24 VDC; 5 to 15 maAs sourcing input (see Trigger Pullup +VCC)Off: +2.2 to +24 VDC; 5 to 15 maOn: 0 to +1.4 VDCTrigger Pullup+VCC**Trigger In Pullup - use ifTrigger In needs sourc-ing (see Note 1 below)+24 VDC recommendedMaximum +30 VDC(**Block contains 1.6k Ohm 1W resistor between Trigger In andTrigger Pullup +VCC)Strobe OutputPullup +VCC*Strobe Supply Voltage -use if Strobe TriggerOutput needs sourcing(see Note 2 below)Based on Strobe requirement (optional)Max: +30 VDC; 50 ma(*Block contains 1.6k Ohm 1W resistor between Strobe TriggerOutput and Strobe Output Pullup +VCC)Strobe TriggerOutput*Trigger Out to Strobe(see Note 3 below)DO NOT APPLY ANY VOLTAGE DIRECTLY TO THIS OUTPUT.DO NOT WIRE OUTPUTS IN PARALLEL.