POWERSCAN ® D8330/M83001425.1.4 RX TimeoutWhen the RS-232 interface is selected, the Host can be used to configure the deviceby sending it command strings (see Appendix A).This parameter can be used to automatically end data reception from the Host afterthe specified period of time.If no character is received from the Host, after the timeout expires, any incompletestring (any string not terminated by ) is flushed from the device buffer.5.2 PEN PARAMETERS5.2.1 Minimum Output PulseThis parameter sets the duration of the output pulse corresponding to the narrowestelement in the barcode. In this way the code resolution is controlled by the signalsent to the decoder, independently of the physical resolution of the code read.The shortest pulse (200 μs) corresponds to a high-resolution code emulation andtherefore a shorter transfer speed to the decoder (for decoders able to work on highresolution codes). Likewise, longer pulses correspond to low-resolution codeemulation and therefore a longer transfer time to the decoder.5.2.2 Conversion to Code 39 and Code 128PowerScan® D8330 Series ReadersWhen using these readers it is possible to convert all codes to Code 39. By disablingthis option the decoded codes will be transmitted in their original format, except forthe following codes, which are ALWAYS converted into Code 39 format:MSI, Code 11, Code 16K, Code 49, GS1 DataBar™.PowerScan® M8300 Series ReadersWhen using these readers it is possible to choose between converting the decodedcodes into either Code 39 format or Code 128 format. It is not possible to disableconversion.