REFERENCES1555.4.5 Time Stamping FormatThe Time Stamping parameter sets the format for hour and date information. It consistsof 1 or 2 groups of numbers, each one made up of 6 decimal digits.For example, setting the Hour/Minutes/Seconds/Month/Day/Year format, theinformation 17:03:16 on June 12, 2002 will be formatted as 170316061202.5.4.6 Time Stamping DelimiterThe Time Stamping Delimiter allows a character to be included to separate the TimeStamping field from the next field in the message. Any character can be included inthe hexadecimal range from 00 to FE.5.5 POWER SAVE5.5.1 Sleep StateWhen using interfaces other than USB, this mode allows the μP in the reader to entera “Sleep” state for minimum power consumption. For D-series readers, this commandis only valid when hardware trigger type is selected.Before entering Sleep mode, the following are verified:• no commands coming from Host• no data being transmitted to Host• Enter Sleep Timeout ended (see par. 5.5.2)To exit Sleep mode press the trigger.For M8300 series readers, sleep state is entered immediately after reading a codeand is not configurable. To exit Sleep mode press the trigger.When using the USB interface, this mode allows the device to manage SelectiveSuspend conditions generated by the Host Operating System in which optimizing lowpower consumption (ex. Windows Stand-by). It is possible to exit the Suspend modeeither from the Host (ex. moving the mouse during Stand-by) or through the barcodereader. The latter, called Remote Wakeup, makes the device wake up the Hostrestoring the communication. Remote Wakeup is possible by pressing the trigger.