DATAVS2-VSM INSTRUCTION MANUAL1255 MONITORING AN INSPECTIONThe “Monitor” mode allows the user to check the correct functioning of the inspection definedpreviously.The chart shown below provides a description of the main modes available and shows howto enable viewing.Mode Example Enable DescriptionStandardThe monitor displays the sensor field focusin full screen mode. The followinginformation is also displayed: Inspection name and relative memoryslot ROI Inspection result Logic value of the outputsToolResultDOWNARROWThis screen shows the tool result of thecurrent inspection.The results of all the inspection tools canbe displayed using the RIGHT/LEFTARROWS.DisplayOnConditionESCBUTTONThis mode displays only the images thatcomply with the condition specified duringinspection configuration using theDataVS2 GUI.ZoomModeUPARROWAn image of the sensor field focus isdisplayed on the monitor with 200% zoom.To move the zoom area, use the ARROWbuttons. Press ESC to exit zoom mode.Statistics SETBUTTONStatistics on the inspection results aredisplayed on the monitor, including: Result Current inspection outcome Execution time (ms) Total inspection execution time Failure (%) % of failed inspections of the totalnumber executed Score Current inspection result Etc…The statistics of the single tools can bedisplayed by pressing STATUS. UseUP/DOWN ARROWS to scroll the toolpanels.Use RIGHT/LEFT ARROWS to changethe scale of the graphics.