DT-6XXX IP-SPOOL Application User’s Manual – Build 12.004/13/06 Datatek Applications Inc. 16parameters. The use of this command is not required if no banner is desired. The bannermay be cleared by using the banner command using the parameter named default. Thiswill delete all banner lines.8.6 APPLICATION COMMENTS - COMMENTSyntax: comment [ L1=”comment”][ L2=”comment”][ L3=”comment”]The comment command allows a user to add user information to the application instance.The information is displayed during a verify command. Up to three lines of informationmay be provided. Each line may be up to 64 characters in length, may include spaces, andis double quoted. Each line may be changed individually. Comments may be cleared bysetting the line value to a null comment (i.e. “”).8.7 L ABELSyntax: label [<“label string”> | none]If the command is issued without arguments, the current configuration is displayed. Whenissued with an argument of none, the label becomes a NULL label. Otherwise, a label upto 32 characters is allowed when enclosed in double quotes. (The double quotes are notcounted as part of the 32 characters). The label may be a mixture of alpha characters anddigits.8.8 OA&M SESSION TIMER CONFIGURATION - TIMEOUTSyntax: timeout [ OFF | ]The timeout command configures the session timer. Its range is 15 to 254 seconds. Whenconfigured, the session timer will disconnect a user from the OA&M telnet port for this IP-SPOOL instance. No other instances on the DT-6XXX are affected since each has its ownOA&M connection.