Manuals database logo
manualsdatabase
Your AI-powered manual search engine

Datum Systems M7 Series Installation And Operation Manual

Page 1 preview
Page 2 preview
Page 3 preview
Page 4 preview
Page 5 preview
Page 6 preview
Page 7 preview
Page 8 preview
Page 9 preview
Page 10 preview
Page 11 preview
Page 12 preview
Page 13 preview
Page 14 preview
Page 15 preview
Page 16 preview
Page 17 preview
Page 18 preview
Page 19 preview
Page 20 preview
Page 21 preview
Page 22 preview
Page 23 preview
Page 24 preview
Page 25 preview
Page 26 preview
Page 27 preview
Page 28 preview
Page 29 preview
Page 30 preview
Page 31 preview
Page 32 preview
Page 33 preview
Page 34 preview
Page 35 preview
Page 36 preview
Page 37 preview
Page 38 preview
Page 39 preview
Page 40 preview
Page 41 preview
Page 42 preview
Page 43 preview
Page 44 preview
Page 45 preview
Page 46 preview
Page 47 preview
Page 48 preview
Page 49 preview
Page 50 preview
Page 51 preview
Page 52 preview
Page 53 preview
Page 54 preview
Page 55 preview
Page 56 preview
Page 57 preview
Page 58 preview
Page 59 preview
Page 60 preview
Page 61 preview
Page 62 preview
Page 63 preview
Page 64 preview
Page 65 preview
Page 66 preview
Page 67 preview
Page 68 preview
Page 69 preview
Page 70 preview
Page 71 preview
Page 72 preview
Page 73 preview
Page 74 preview
Page 75 preview
Page 76 preview
Page 77 preview
Page 78 preview
Page 79 preview
Page 80 preview
Page 81 preview
Page 82 preview
Page 83 preview
Page 84 preview
Page 85 preview
Page 86 preview
Page 87 preview
Page 88 preview
Page 89 preview
Page 90 preview
Page 91 preview
Page 92 preview
Page 93 preview
Page 94 preview
Page 95 preview
Page 96 preview
Page 97 preview
Page 98 preview
Page 99 preview
Page 100 preview
Page 101 preview
Page 102 preview
Page 103 preview
Page 104 preview
Page 105 preview
Page 106 preview
Page 107 preview
Page 108 preview
Page 109 preview
Page 110 preview
Page 111 preview
Page 112 preview
Page 113 preview
Page 114 preview
Page 115 preview
Page 116 preview
Page 117 preview
Page 118 preview
Page 119 preview
Page 120 preview
Page 121 preview
Page 122 preview
Page 123 preview
Page 124 preview
Page 125 preview
Page 126 preview
Page 127 preview
Page 128 preview
Page 129 preview
Page 130 preview
Page 131 preview
Page 132 preview
Page 133 preview
Page 134 preview
Page 135 preview
Page 136 preview
Page 137 preview
Page 138 preview
Page 139 preview
Page 140 preview
Page 141 preview
Page 142 preview
Page 143 preview
Page 144 preview
Page 145 preview
Page 146 preview
Page 147 preview
Page 148 preview
Page 149 preview
Page 150 preview
Page 151 preview
Page 152 preview
Page 153 preview
Page 154 preview
Page 155 preview
Page 156 preview
Page 157 preview
Page 158 preview
Page 159 preview
Page 160 preview
Page 161 preview
Page 162 preview
Page 163 preview
Page 164 preview
Page 165 preview
Page 166 preview
Page 167 preview
Page 168 preview
Page 169 preview
Page 170 preview
Page 171 preview
Page 172 preview
Page 173 preview
Page 174 preview
Page 175 preview
Page 176 preview
Page 177 preview
Page 178 preview
Page 179 preview
Page 180 preview
Page 181 preview
Page 182 preview
Page 183 preview
Page 184 preview
Page 185 preview
Page 186 preview
Page 187 preview
Page 188 preview
Page 189 preview
Page 190 preview
Contents
  1. installation and operation manual
  2. Table Of Contents
  3. Table Of Contents
  4. Table Of Contents
  5. Table Of Contents
  6. rohs compliance
  7. about this manual
  8. Introduction
  9. Figure 1-2 – Point-to-Point Network
  10. Figure 1-3 – Four (4) Site Point-to-Multipoint Network
  11. What's New – This Modem and This Manual
  12. Figure 1-6 – M7LT Terminal (showing front and rear views)
  13. M7 Modem Assemblies
  14. Figure 1-8 - Modem Block Diagram
  15. M7 Capabilities
  16. Figure 1-10 – Carrier Alpha = 0.08, 1Msps x1.10 Carrier Spacing
  17. Figure 1-11 - Synchronous Serial Interface
  18. Figure 1-12 - Ethernet Interface (I7)
  19. Figure 1-13 – Express Ethernet Interface (E7)
  20. Figure 1-14 - Dual G.703/E1 Interface (G7)
  21. Figure 1-15 - HSSI Interface
  22. Figure 1-17 - Dual Interface Configuration I7 and G7
  23. Table 1-2 – Internal Framing Options
  24. Forward Error Correction (FEC) Options
  25. Figure 1-19 - Reed-Solomon Block Diagram
  26. Figure 1-20 - TCP Option Card
  27. M7 Series Feature Sets
  28. Installation Requirements
  29. Modem Connections
  30. Figure 2-3 – M7LT Rear Panel with DC Prime Power Input
  31. Table 2-2 - Remote Control Connector Pinout (J5)
  32. Figure 2-4 – M7LT Rear Panel Connector Options (N Type or F Type)
  33. Figure 2-5 – M7LT Rear Panel indicators
  34. Figure 2-6 – M7LT Internal BUC Power Supply (AC version shown)
  35. Table 2-6 – Synchronous Serial Data Interface Connector Pinout (J11)
  36. Table 2-7 – Serial Interface Overhead Channel - IBS Standard Mux - RS-232 (J10)
  37. Table 2-9 – Serial Interface Overhead Channel - Advanced/IBS Custom Mux - RS-232 (J10)
  38. Table 2-10 – Serial Interface Overhead Channel - Advanced/IBS Custom Mux - RS-485 (J10)
  39. Figure 2-8 – I7 - IP Interface Rear Panel
  40. Figure 2-9 - Express Ethernet Interface (E7)
  41. Figure 2-11 – G7 - Dual G.703/E1 Interface Rear Panel
  42. Table 2-15 - Overhead Interface - RS-232 (J20)
  43. Figure 2-13 – HSSI Interface Rear Panel
  44. Table 2-17 – M7 Overhead Channel - IBS Standard Mux - RS-232 (J25)
  45. Table 2-19 – M7 Overhead Channel - Advanced/IBS Custom Mux - RS-232 (J25)
  46. Table 2-20 – M7 Overhead Channel - Advanced/IBS Custom Mux - RS-485 (J25)
  47. Adding or Changing the Interface Type
  48. Figure 2-15 - FEC Option Card Installation
  49. Redundancy Connection (Future Option)
  50. Operation
  51. Table 3-1 - Modem LED Indicators
  52. Front Panel Control and Monitor Matrix
  53. Web Browser Operation
  54. Figure 3-4 - M7 Web Browser Page Sections
  55. Figure 3-5 - Summary Status Page
  56. Figure 3-6 - Unit Status Page
  57. Figure 3-8 – Unit Events Log Page
  58. Figure 3-9 - Unit Remote IP Control Interface Pages
  59. Figure 3-11 - Unit HTTP Page
  60. Figure 3-13 – Modulator Status Page
  61. Figure 3-15 – Modulator Data Interface Page
  62. Figure 3-17 – Demodulator Status Page
  63. Figure 3-19 – Demodulator Data Interface Page
  64. Figure 3-21 – Demodulator Monitor Constellation Page
  65. Figure 3-22 – Demodulator Monitor Spectrum Analyzer Page
  66. Figure 3-23 - Serial Synchronous Interface Status Page
  67. Figure 3-24 - Serial Synchronous Interface I/O Page
  68. Figure 3-26 - Serial Synchronous Interface ESC Interface Page
  69. Figure 3-28 – Serial Synchronous Interface Event Page
  70. Figure 3-29 – I7 Interface Status Page
  71. Figure 3-32 – I7 Interface Event Page
  72. Figure 3-33 - I7 Interface Statistics Page
  73. Figure 3-34 – E7 Interface Status Page
  74. Figure 3-36 - E7 Interface I/O Port Configuration Page
  75. Figure 3-40 – Dual G.703 Interface Send Mux Page
  76. Figure 3-41 – Dual G.703 I/O Port 1 Page (showing D&I selections)
  77. Figure 3-42 – Dual G.703 Interface Event Page
  78. Front Panel Monitor and Control Parameters
  79. Table 3-5 - Modem (Unit) Parameter Detail
  80. Table 3-6 - Modulator Parameter Detail
  81. Table 3-7 - Demodulator Parameter Detail
  82. Table 3-8 – Synchronous Interface Parameter Detail
  83. Table 3-9 – I7 - IP Interface Parameter Detail
  84. Table 3-10 – E7- Express Ethernet Interface Parameter Detail
  85. Table 3-11 – G7 – Dual G.703/E1 Interface Parameter Detail
  86. Table 3-12 – High Speed Serial Interface (HSSI) Parameter Detail
  87. Remote Command Interface Control
  88. Figure 3-43 - Alarm Processing
  89. Table 3-13 – ASCII Characters Available for Unit Station ID
  90. Data Interface Options - Technical Details
  91. Figure 3-44 - Express Ethernet Interface Block Diagram
  92. Figure 3-45 - Point-to-Point Satellite Network
  93. Figure 3-46 - Point-to-Multipoint Satellite Network
  94. Figure 3-48 – Four site Mesh network example
  95. Figure 3-49 – Configuration of a Mesh network site with a spare demodulator
  96. Data Interface Clock Options
  97. Figure 3-50 – Modulator Clock Source Options
  98. Figure 3-51 – Demodulator Clock Source Options
  99. Automatic Uplink Power Control (AUPC) Operation
  100. Figure 3-52 – AUPC Remote Enabled Network
  101. Figure 3-53 – Hub Modulator with optional AUPC Demodulator
  102. Figure 3-54 – Point-to-Multipoint AUPC configuration for a four (4) site network
  103. Special Control Mechanisms
  104. Storing and Recalling Configuration
  105. Built-in 1:1 Redundancy Mode Operation (Future Option)
  106. Maintenance
  107. Internal Modem Test Functions
  108. Troubleshooting
  109. Updating Modem Firmware
  110. Upgrading the Modem Feature Set
  111. Figure 4-3 – Modulator Feature Page
  112. Frequently Asked Questions - FAQ
/ 190
Related manuals for Datum Systems M7 Series
Datum Systems M7XC Installation And Operation Manual first page preview
Datum Systems M7XC Installation And Operation Manual
Datum Systems PSM-500 Installation And Operation Manual first page preview
Datum Systems PSM-500 Installation And Operation Manual
Datum Systems PSM-4900L Application Manual first page preview
Datum Systems PSM-4900L Application Manual
Datum Systems PSM-2100L User Manual first page preview
Datum Systems PSM-2100L User Manual
Datum Systems PSM-500 Series Appendix first page preview
Datum Systems PSM-500 Series Appendix
This manual is suitable for:
M7 SeriesM7D SeriesM7DL SeriesM7L SeriesM7LT Series
Manuals database logo
manualsdatabase
Your AI-powered manual search engine