298 Gas installationIMPORTANT NOTEThis appliance is supplied for use on NATURAL GAS only and cannot be used on any othergas without modification.This appliance is manufactured for conversion to LPG and is supplied with a conversion kit.The cooker must be installed by a qualified person in accordance with the Gas Safety(Installation and Use) (Amendment) Regulation 1990 and the relevant building/l.E.E.Regulations.The following British Standards should be used as reference when installing this appliance.BS6172 1990, BS5440 part 2 1989 and BS6891 1988.Failure to install the appliance correctly could invalidate any manufacturers warranty andlead to prosecution under the above quoted regulation.In the UK C.O.R.G.I registered installers are authorised to undertake the installation andservice work in compliance with the above regulations.Gas connectionThe installation of the cooker to Natural Gas or LP Gas must be carried out by a qualified gasengineer. Installer shall take due account of the provisions of the relevant British StandardsCode of Practice, the Gas Safety Regulations and the Building Standards (Scotland)(Consolidation) Regulations issued by the Scottish Development Department.Installation to Natural GasInstallation to Natural Gas must conform to the Code of Practice, etc. The supply pressurefor Natural Gas is 20 mbar.