19GENERAL• The connection to the electrical net-work must be carried out by qualifiedpersonnel and must be according toexisting norms.• The appliance must be connected tothe electrical network verifying aboveall that the voltage corresponds to thevalue indicated on the specificationsplate and that the cables section ofthe electrical plant can bear the loadwhich is also indicated on the plate.• The appliance can be connecteddirectly to the mains placing anomnipolar switch with minimum open-ing between the contacts of 3 mmbetween the appliance and the mains.• The power supply cable must nottouch the hot parts and must be posi-tioned so that it does not exceed75°C at any point.• Once the appliance has beeninstalled, the switch must always beaccessible.• If the power supply cable is damagedit must be substituted by a suitablecable.The connection of the appliance tothe grounding unit is mandatory.The manufacturer declines everyresponsability for any inconve-nience resulting from the inobser-vance of this condition.Before effecting any interventionon the electrical parts the appli-ance must be disconnected fromthe network.7 E L E C T R I C A L S E C T I O NFEEDER CABLE SECTIONType HO5RR-F or H05VV-F230 V ~ 3 x 2,5 mm 2 (**)(**) – Connection to wall-mountingdistribution panel.IMPORTANT: this double ovenmust be connected to a suitabledouble pole control unit adjacentto the oven.NO DIVERSITY CAN BE APPLIEDTO THIS CONTROL UNIT.