214 CONFIGURATION OF THE CONTROL PANELThe universal control unit NET24N can be used for the management of the following types ( ) of closures motorized by DEASystem: swing and sliding gates, overhead doors and barriers.In order to ensure maximum adaptability to each of closure, the control board provides an initial procedure, performed onlyat the first turn, for the optimal configuration of inputs, outputs and parameters (see diagram ). Once configured, the control panelwill operate in the mode “dedicated” to the of selected closing. After performing the initial configuration it is sufficient to executethe standard programming for the installation on which it is operating.All settings remain in memory even in the case of subsequent flare-ups (see diagram ).If necessary the of configured closing can be later adjusted following diagram .FIRST CONTROL BOARD IGNITIONConfiguration after the first ignitionFor the first control panel ignition, proceed asfollows:1. Apply power, the display shows in sequence thewriting “ ” and “ ” flashing;2. Press the button and hold for 5 seconds untilthe display shows on the display;3. Acting on the and keys, select the desiredconfiguration depending on the type of installa-tion (es. ) and confirm by pressing thebutton;At this point, the selection will be stored andreloaded each time in the future.4. Follow signs, “ ”, “ ” followed by thesymbol of closed gate “----”.Following ignitionsIf you have already saved a configuration, pro-ceed as follows:Apply power, the display shows in sequence thewriting “ ”, “ ”, “ ” followed by thesymbol of closed gate “----”.Modify the existing configurationIf you have already saved a configuration andyou want to change it, proceed as follows:1. Hold down the button and give power, thedisplay shows in sequence the writing “ ”and “ ” flashing;2. Press the button and hold for 5 seconds untilthe display shows (the value changes tomatch the previous configuration used) on thedisplay;3. Acting on the and , select the new desiredconfiguration depending on the type of installa-tion (es. ) and confirm by pressing thebutton;Stop the reconfiguration procedure priorto confirmation, involves loading the pre-vious configuration by the control panel wi-thout any modification.However, if the reconfiguration proce-dure is brought to an end, the new confi-guration will take the place of the previousone and will be reloaded each time in thefuture.4. Follow signs, “ ”, “ ” followed by thesymbol of closed gate “----”.Sliding gatesSwing gatesOverhead doorsBarriers