225 ELECTRICAL CONNECTIONSExecute the wiring following the directions of table 1 and diagrams on page 23.WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mmin the open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliarycircuits power supply), and fasten the latter with appropriate clamps near the terminal boards.WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensuremulti pole disconnection from the power supply, with a contact opening of 3 mm.WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm 2.Table 1 “terminal board connections”1-2 +24 V power supply output for auxiliary devices 200mA3-4 22 V ~ transformer power supply input5-6 24 V battery power supply or photovoltaic accumulator Green Energy input (follow carefully polarityindications).7-8 Operator 1 output9 Connection of motors metallic parts10-11 Operator 2 output (if present)12-13 24 V max 15 W output for open gate fix/flashing warning light (if P052=0/1) or courtesy light (if P052>1)14-1514 (-) “Boost” output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1),step by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output forelectric-lock power supply via external relay (if P062=4), output for electro-magnets power supply forbarriers (ifP062=5) or temporized output (if P062>5).15 (+)16-17 24 V Flashing light output max 15W art. Lumy/24A/STYPE 00 TYPE 01 TYPE 02 TYPE 03If the installation requires different commands and / or ad-ditional to the standard, you can configure each input tothe required rate.Refer to Chapter“Advanced Programming”.If unused, short circuit18 Input 6 (FCC 1) (STOP) (NONE) (NONE)19 - Com N.C. N.C. N.O. N.O.20 Input 5 (FCA 1) (PHOTO 2) (NONE) (NONE)21 - Com N.C. N.C. N.O. N.O.22 Input 4 ( PHOTO 1) (PHOTO 1) (STOP) (NONE)23 - Com N.C. N.C. N.C. N.O.24 Input 3 (SAFETY) (SAFETY) (SAFETY) (NONE)25 - Com N.C. N.C. N.C. N.O.26 Input 2 (PEDESTRIAN) (PEDESTRIAN) (PHOTO 1) (PHOTO 1)27 - Com N.O. N.O. N.C. N.C.28 Input 1 (START) (START) (START) (START)29 - Com N.O. N.O. N.O. N.O.30 Aerial signal input31 Ground aerial input32-33 32 (+)DE@NET mains input (unused at the moment)33 (-)J5 J9 Encoder selection Jumper:•A position = operators with encoder (remind to set P029=0)•B position = operators without encoder (remind to set P029=1)AB AB