6.6 Building Block Video TX400DCUp the coax controlThe controller telemetry will output BBV protocolsThe Dome address switches need to be set to DEN PANEL(Refer to the Operation/Installation Manual, supplied with each Dome, for an explanation on accessto, and setting of, the address switches)Blue rotary address switch set to F…. Yellow rotary address switch set to D.This is the default setting for the domes unless specified otherwise.NB If the dome is supplied with a remote protocol converter in the PSU box, then theaddress switches will be factory set to: Yellow = 1 Blue = 0STORING PRESET POSITIONS:Note that, in this configuration, it may be quicker to use the Dennard/DM controller softwarerather than using the Dome software.Move the camera to the desired position.Press and hold the ‘Program’ key then press the number key you want to use to identify the preset.(Note that only eight preset positions can be set using this controller.) At this stage the preset menufrom the dome will be displayed on the screen enabling you to key in a preset identification. If youdon’t want to add a preset identification, move the cursor down to the ‘Accept entry’ line and acceptby pressing key number 1. Text can be entered by moving the cursor under each letter/number inturn, using the joystick, and then pressing key number 1 to accept.When you have finished entering text, close the menu by moving the cursor down to the ‘Acceptentry’ line and accept by pressing key number 1.DOME PROGRAMMING:To access the dome menu:Press and hold the # key then press No 1 keyThis will give you access to the Operator menu. The Supervisor menu and Technicians menu canbe accessed from this point. The number 1 key is used to enter/accept2040 / 2060 Menu System Manual Page. 36