10 Part Number: 9291455 08/17Installation Section 2Model &Export Option# of 1/3 Size PansIn RailAdapter BarsRefrigerated Countertop Prep RailCTP8146-NBCTP8146-NB-E4 5CTP8160-NBCTP8160-NB-E6 7Electrical ServiceDANGERCheck all wiring connections, including factory terminals,before operation. Connections can become loose duringshipment and installation.nWarningThis appliance must be grounded and all field wiring mustconform to all applicable local and national codes. Referto rating plate for proper voltage. It is the responsibility ofthe end user to provide the disconnect means to satisfythe authority having jurisdiction.• Plug units with R290 refrigerant into a receptacle that is aminimum of 14” (36cm) above the floor.• All electrical work, including wire routing and grounding,must conform to local, state and national electrical codes.• The equipment must be grounded.• A separate fuse/circuit breaker must be provided for eachunit.• The maximum allowable voltage variation is ±10% of therated voltage at equipment start-up (when the electricalload is highest).• If optional electrical receptacles are mounted in the unit’sbacksplash, they must be wired independently from theexisting unit wiring.• Check all green ground screws, cables and wireconnections to verify they are tight before start-up.Ground Fault Circuit InterrupterGround Fault Circuit Interrupter (GFCI/GFI) protection is asystem that shuts down the electric circuit (opens it) when itsenses an unexpected loss of power, presumably to ground.Welbilt does not recommend the use of GFCI/GFI circuitprotection to energize our equipment. If code requires theuse of a GFCI/GFI then you must follow the local code. Thecircuit must be dedicated, sized properly and there mustbe a panel GFCI/GFI breaker. We do not recommend theuse of GFCI/GFI outlets to energize our equipment as theyare known for more intermittent nuisance trips than panelbreakers.Model Amps H.P. NEMA Plug Voltage,Hertz,PhaseRefrigerated Work Table With Backsplash18648BSTMP 2.9 0.205-15P 115, 60, 118660BSTMP 2.9 0.2018672BSTMP 2.9 0.2018691BSTMP 4.8 0.2518699BSTMP 4.8 0.25186114BSTMP 6.3 0.33Optional Export Refrigerated Work Table With Backsplash18648BST-E 2.5 1/4Varies PerDestination230-240,50, 118660BST-E 2.8 1/318672BST-E 5.3 1/218691BST-E 5.3 1/218699BST-E 5.3 1/2186114BST-E 5.0 3/4Refrigerated Work Table18648BUCMP 2.9 0.205-15P 115, 60, 118660BUCMP 2.9 0.2018672BUCMP 4.8 0.2018691BUCMP 4.8 0.2518699BUCMP 4.8 0.25186114BUCMP 6.3 0.33Optional Export Refrigerated Work Table18648BUC-E 2.5 1/4Varies PerDestination230-240,50, 118660BUC-E 2.8 1/318672BUC-E 5.3 1/218691BUC-E 5.3 1/218699BUC-E 5.3 1/2186114BUC-E 5.0 3/4Refrigerated Pizza Prep Table With Raised Rail18648PTBMP 4.7 0.255-15P 115, 60, 118660PTBMP 4.7 0.2518672PTBMP 6.5 (2) .2018691PTBMP 6.5 (2) .2018699PTBMP 6.5 (2) .20186114PTBMP 6.5 (2) .20Optional Export Refrigerated Pizza Prep Table With Raised Rail18648PTB-E 2.5 1/4Varies PerDestination230-240,50, 118660PTB-E 2.8 1/318672PTB-E 5.3 1/218691PTB-E 5.3 1/218699PTB-E 5.3 1/2186114PTB-E 5.0 3/4Refrigerated Pizza Prep Table With Dual LiquiTec® Rails18648PDLV 10.1 1/5, 1/3 5-20P 115, 60, 118672PDLV 12.7 1/5, 1/2 5-20P 115, 60, 1Refrigerated Pizza Prep Table With LiquiTec® Rail18648PTLV 7.0 1/4 5-15P 115, 60, 118672PTLV 14.0 1/2 5-20P 115, 60, 118699PTLV 14.0 1/2 5-20P 115, 60, 1Optional Export Refrigerated Pizza Prep Table With LiquiTec® Rail18648PTL-E2.5 1/4 Varies PerDestination230-240,50, 118672PTL-E18699PTL-E